Electrical Requirements; Important - Robam JJZ(Y/T)-G517K Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by
not less than ¹/₄" (0.64 cm) flame retardant millboard covered with not less than No.
28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the cooking and
the bottom of an uncovered wood or metal cabinet.

ELECTRICAL REQUIREMENTS

IMPORTANT: Use a 3-wire, UL listed, 30-amp minimum supply cord (pigtail); or if
local codes do not permit grounding through the neutral, use a 4-wire UL listed,
30-amp minumum power supply cord rated at 250 volts and intended for use with
ranges.
If codes permit and a separate ground wire is used, it is recommended that a
qualified electrical installer determine that the ground path is adequate and wire
gauge is in accordance with local codes.
To properly install your range, you must determine the type of electrical connection
you will be using and follow the instructions provided for it here.
Range must be connected to the proper electrical voltage and frequency as
specified on the model/serial number rating plate. All models are dual rated, and
designed to be connected to either 120/240V or 120/208V AC, 60Hz, single-
phase, 3-wire or 4-wire, power supply.
Voltage and
Frequency
240V, 60 Hz
208V, 60 Hz
When a 4-wire, single-phase 120/240 volt, 60 Hz., AC only electrical supply is
available, a 25-amp maximum circuit protection is required (or, if specified on
the model/serial rating plate, when a 4-wire, single phase 120/208 volt 60 Hz.,
AC only electrical supply is available, a 20-amp maximum circuit protection is
required).
For direct wire installations, install a suitable conduit box (not furnished). An
appropriately sized, UL conduit connector must be used to correctly attach the
conduit to the junction box.
IMPORTANT: Local Codes may vary; installation electrical connections and
grounding must comply with all applicable local codes.
If local codes permit grounding through the electrical supply neutral, connect both
the white neutral wire and the green ground wire from the oven to the white neutral
electrical supply wire.
ELECTRICAL REQUIREMENTS - U.S.A. ONLY
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate and in
conformance with the National Electrical Code, ANSI/ NFPA No. 70-latest edition
and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
Amps
Circuit Required
25 Amp Circuit
20A
20 Amp Circuit
17.4A
Dual Fuel Range
9