Power Cord Replacement; Residual Risks; Technical Specifications - Ferm CDM1121P Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
b) Use power tools only with specifically
designated battery packs. Use of any other
battery packs may create a risk of injury and
fire.
c) When battery pack is not in use, keep it
away from other metal objects, like paper
clips, coins, keys, nails, screws or other
small metal objects, that can make a
connection from one terminal to another.
Shorting the battery terminals together may
cause burns or a fire.
d) Under abusive conditions, liquid may be
ejected from the battery; avoid contact.
If contact accidentally occurs, flush with
water. If liquid contacts eyes, additionally
seek medical help. Liquid ejected from the
battery may cause irritation or burns.
Service
a) Have your power tool serviced by a
qualified repair person using only identical
replacement parts. This will ensure that the
safety of the power tool is maintained.
For the charger
Intended use
Charge only 14.4V or 18.0V MAX 2.0Ah Li-ion
type rechargeable battery packs. Other types of
batteries may burst causing personal injury and
damage.
a) The appliance is not to be used by persons
(including children) with reduced physical,
sensory or mental capabilities, or lack of
experience and knowledge, unless they
have been given supervision or instruction
b) Children being supervised not to play with
the appliance
c) Do not recharging non-rechargeable batteries!
d) During charging, batteries must be placed in
the well ventilated area!

Residual risks

Even when the power tool is used as
prescribed it is not possible to eliminate all
residual risk factors. The following hazards
may arise in connection with the power tool's
construction and design:
6
a) Health defects resulting from vibration
emission if the power tool is being used
over longer period of time or not adequately
managed and properly maintained.
b) Injuries and damage to property to due to
broken accessories that are suddenly dashed.
Warning! This power tool produces an
electromagnetic field during operation.
This field may under some circumstances
interfere with active or passive medical
implants. To reduce the risk of serious or
fatal injury, we recommend persons with
medical implants to consult their
physician and the medical implant
manufacturer before operating this
power tool.

Power cord replacement

If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
2. MACHINE INFORMATION
Intended use
This cordless drill is intended for driving in and
loosening screws as well as for drilling in wood,
metal and plastic.

Technical specifications

Model No
Charger
Input of charger
Output of charger
Rechargeable Battery pack
Battery charging time
Chuck capacity
Torque settings
No load speed
Position 1:
Position 2:
Weight (incl. battery)
Sound pressure level L
PA
CDM1121P CDM1122P
CDA1080S
230-240 V ~ 50Hz 45W
10.8-18V DC 2A
14,4 V
18 V
Li-ion 2.0Ah
Li-ion 2.0Ah
1.2 hour
1.5-13 mm
23 + Drill mode
0-400 /min
0-1400 /min
1,54 kg
1,59 kg
66.23 dB(A)
66.40 dB(A)
K=3 dB(A)
K=3 dB(A)