A l a r m
↑ ↓
↑ ↓
A l a r m
S e n s i t i v i t y
M e t h o d
- - - - - - - - - - - -
- - - - - - - - - - - -
↑ ↓
↑ ↓
Displays the date the detector was last serviced.
L a s t
↑ ↓
↑ ↓
S e r v i c e D a t e
D D M M M Y Y Y Y
↑ ↓
↑ ↓
Displays whether the green LED on the detector is set to "Blink" or
D e v i c e ' s
↑ ↓
↑ ↓
"No Blink" in normal conditions.
L E D S e t t o :
- - - - - - - - - - - -
↑ ↓
↑ ↓
P r o d u c e d
↑ ↑
Displays the date of manufacture
i n :
M M M Y Y Y Y
3: WRITE DETECTOR SETTINGS
Selects and writes new settings to the detector.
W r i t e
↑ ↓ 3
↑ ↓
D e t e c t o r
S e t t i n g s
O K
S e l e c t A d d r .
D e v i c e
↓ ↓ 3 . 1
O K
a n d p r e s s O K
A d d r e s s
0 1
↓ ↑
↓ ↑
N E W A l a r m
A l a r m
↓ ↑ 3 . 2
↓ ↑
O K
S e n s i t i v i t y
S e n s i t i v i t y
- - - - - -
↓ ↑
↓ ↑
S e t L E D
L E D
↓ ↑3 . 3
↓ ↑
O p e r a t i o n
O p e r a t i o n
O K
- - - - - -
↓ ↑
↓ ↑
S i r e n S o u n d
S i r e n
↓ ↑3 . 4
↓ ↑
O K
s e t t o :
O p e r a t i o n
X
↓ ↑
↓ ↑
↓ ↑ O K
↓ ↑
S t a r t
A t t e m p t i n g
O K
t o T r a n s m i t
C o n n e c t i o n
N E W S e t t i n g s
L I N K ? . . . > E N D
↓ ↑
↓ ↑
Success
Transmits new settings to the detector. The "Attempting Connection" Screen will
be displayed for a few seconds, and a bar graph will be displayed indicating progress.
On completion of programming, the RPTU will either return to the "Start Transmis-
sion" screen or the "Connection Failed" screen as appropriate.
Important: Once transmission of the new settings has started, it is essential
that the procedure be allowed to complete.
Immediately following completion of the write sequence, the new
settings should be verified using "Read Detector Setting".
S t a r t
↑ ↑ O K
The Incremental Address mode will automatically program detectors
I N C R E M E N T A L
with sequential addresses. Use the arrows to select the initial address
A d d r e s s M o d e
in a sequence, and then press OK to program the detector. On
O K
completion, the next address will automatically be selected, press OK
to program the next detector.
S e l e c t A d d r .
O K
a n d p r e s s O K
0 0 1
Success
E s c
4: WRITE NEW SERVICE DATE
W r i t e
↑ ↓ 4
↑ ↓ 4
N E W
S e r v i c e D a t e
O K
O K
A t t e m p t i n g
C o n n e c t i o n
Fail
C o n n e c t i o n
F a i l e d
L I N K ? . . . > E N D
* * R e t r y ? * *
L a s t
↑ ↓
↑ ↓
C o n t a m i n a t e d
S e r v i c e D a t e
I n v a l i d
D D M M Y Y
Will display "Alarm Sensitivity" for
photo and photo-thermal or "Alarm
Method" for thermal detectors.
Level will be "Low", "Medium" or
"High"
↑ ↓
↑ ↓
Method will be "Fixed Temp" or "Rate
of Rise"
Use arrows to select the required
address (01 to 99) and press OK to
confirm.
O K
Use arrows to select alarm
sensitivity (LOW / MEDIUM /
HIGH) and press OK to confirm.
Note: Detectors are supplied set to
↓ ↑ O K
↓ ↑
Medium sensitivity as default.
O K
Use arrows to select
No-Blink - LED off on standby
Blink - Green LED Blinking on
↓ ↑O K
↓ ↑
standby
O K
Use arrows to select siren sound -
from 1 up to 6
Note:
This function is not yet
↓ ↑O K
↓ ↑
available
O K
C o n n e c t i o n
F a i l
f a i l e d
* * R e t r y ? * *
O K
A t t e m p t i n g
C o n n e c t i o n
F a i l
f a i l e d
C o n n e c t i o n
L I N K ? . . . > E N D
* * R e t r y ? * *
O K
If the detector has been satisfactorily
serviced, this function will write the current
date to the detector as it's new service date,
otherwise the S300RPTU will display a
warning that the detector is dirty or
contaminated. If the date has been
correctly programmed, the current date will
Esc
be displayed on the S300 RPTU screen.

5: ALARM TEST

This will force the detector to run a chamber test and, provided the chamber is good, set the alarm
flag to put the detector into alarm. If the chamber is faulty or contaminated the relevant screen will be
↑ ↓ 5
↑ ↓
Alarm
Test
Press OK x 2
O K
O K
Attempting
Connection
LINK?...END
Device set
to Alarm
6: OTHER SCREENS
Other screens that may appear at any time include the following:
Batteries in the S300RPTU need replacing. With reference to the diagram on the front page:
L o w B a t t e r y
i n R P T U
WARNING: Do not remove the back up button cell
clock information to be lost, and the unit to stop working. Do not tamper with any part of
the circuit except the main batteries or permanent damage may be caused.
L o w B a t t e r y
i n S 3 0 0 S A T
R P T U
F a u l t y !
G o o d b y e . . .
7: S300SAT SATELLITE TEST UNIT
The S300SAT provides a radio link for communications between the S300RPTU tool and a series 300
detector over distances up to approximately 4.5m. It clips directly into position on the detector, with
the use of either a standard System Sensor or, via an adaptor, No Climb Products access poles.
To prevent cross communication where more than one unit is in use on a single site, the S300SAT and
S300RPTU may be set to an address for 00 to 15 - See RPTU setup for details.
E s c
Power On/Off
E s c
Switch
Power
Indicator
LED
displayed on the RPTU.
Note: Before running this test, notify the
proper authorities that the detector is
undergoing test.
Once the detector has been set into
alarm, communications with the
O K
Esc
S300RPTU will be lost, and the detector
Connection
will need to be reset from the control
Fail
Failed
panel.
** Retry **
Press OK to return to the main menu
Chamber
Contaminated
F A U L T Y
Invalid
Replace Unit
The battery is accessed by unscrewing the four screws
removing the rear cover.
Replacement batteries
are 3 x LR03.AAA Size 1.5V. Ensure that
correct polarity is used.
at any time. This will cause RPTU
Batteries in the S300STU Satellite unit need replacing. See S300STU
instructions below for details.
Loss of information on the real time clock on the RPTU. This will disable
any further operation except to turn the unit off.
Note:
If this message appears, the S300 RPTU must be returned to
System Sensor for repair and reprogramming.
Displayed when the S300RPTU is switched off.
To locate the S300SAT, locate the unit
over the detector, and rotate until it
drops into place. Apply gentle
pressure to press home. To remove
simply pull unit away from detector
and
Battery Compartment.
Takes 2 x MN1604
(6LR61) 9V alkaline
batteries (Not supplied)