8.
SPECIFICATIONS
Model
Product standards
Type of apparatus
Power Supply
Recommend battery type
Sensor Type
Product life
Standby Current
Alarm Current
Operation Ambient Condition
Storage/Transport Ambient Condition
Alarm sound
Low Battery warning silence
Installation Location
Detection range
Size
Weight
NOTE: This CO alarm is designed to detect carbon monoxide gas from any source of combustion. It is not designed to
detect any other gas.
9.
SYMBOLS
Recycling and Disposal: The WEEE symbol indicates that this product and its batteries must be disposed of separately
from household waste. When this product reaches the end of its service life, take it to a designated waste collection
point nearby to ensure safe disposal or recycling. Protect the environment and human health, use natural resources
responsibly!
Updates or new warnings might apply to the manual. Always check the most up to date manual on
before installing or reinstalling the product. Read the manual before use and keep it in a safe place for future use
and maintenance.
Guarantee visit
ELRO Europe |
Postbus 9607 - Box E800
1006 GC Amsterdam - The Netherlands
www.elro.eu
www.elro.eu
: CBFC28
: EN 50291-1:2018
: Type B
: 3V (2pcs AA alkaline battery)
: GP GN15A or ENERGIZER E91
(The normal service life is 3years)
: Electrochemical
: 10 years after activation
: <20μA (average)
: <50mA (average)
: -10 ~ +45°C, 25 ~ 95%RH
: -20 ~ +50°C, 10 ~95%RH
: ≥85DB at 3m
: about 9 hours
: Wall
: Max. 40 m2 within a room.
: 120 x 80 x 37 ± 1mm
: 102 ± 5g (net)
- 7 -
www.elro.eu