Front panel
6. Control panel
7. Exhaust vent
8. Carbon filter
9. Compartment grid of the carbon filter
Control panel
10. On/Off key.
11. Timer key: programs automatic start-up of the appliance
12. Humidity/timer key: selects preferred level of humidity when the appliance is running in dehumidifier mode or the
dehumidifying time when programming the timer.
13. Humidity/timer key: selects preferred level of humidity when the appliance is running in dehumidifier mode or the
dehumidifying time when programming the timer.
14. Control screen
15. Anti-freeze indicator: indicates that the appliance is in anti-freeze mode
16. Timer indicator: the timer indicator light comes on when the time is set. The light flashes when adjusting the operating
time.
17. Operating indicator: when the dehumidifier is connected, the operating indicator light flashes. Once the dehumidifier
is running, the indicator light is permanently green.
18. Collection tank indicator: the water indicator light flashes when the water collection tank is full. At this point, the
appliance switches to stand-by mode.
INSTALLATION
• Check that the water tank is empty before using the dehumidifier.
• To save energy and improve performance, close all doors and windows when the dehumidifier is on.
• The dehumidifier must be placed as close as possible to the source of humidity.
• T o reduce the noise and vibrations produced by the appliance, we recommend the use of an anti-vibrations mat. These
mats are available from specialist stores.
Installing the water tank
Check that the water tank is empty prior to each use. To do this, empty the tank, following the instructions below:
• Check that the appliance is turned off and unplugged before emptying the tank.
• Place your hand on the sides of the water tank and remove it .
• Remove the cover located above the tank and empty the water.
• Replace the cover before refitting the tank.
Note: When the water tank is full, the appliance will immediately stop running. The water tank icon (18) will start to
flash.
Installing the drainage pipe
If the appliance is used in a very humid environment, it may be fitted with a permanent drainage connection (supplied) as
shown below:
• Switch off the dehumidifier and disconnect it.
• Remove the plug on the tank's cover (figure 1) and put it in the hole provided for this purpose at the back of the dehumi-
difier.
• Cut the cover located at the back of the appliance using scissors or a pair of pliers (not supplied) (figure 2).
• Insert the pipe (supplied) into the drainage hole, checking that this fits to avoid any risk of water leakage (figure 3).
Installing the carbon filter
The dehumidifier is fitted with a carbon filter in addition to the air filter located under the grid. This carbon filter clears the
room of unpleasant odours.
Dehumidifi er S1
EN
5