Caution
The C-TOP+ contains electrostatically sensitive components.
Electrostatic discharge caused by improper handling or incorrect earthing can
damage the internal electronics.
• Observe the handling specifications for electrostatically sensitive devices.
• Discharge yourself from static discharges before assembling or disassembling
modules to protect the modules.
• Assemble the housing of the C-TOP+ to earthed drive units in an electrically
conductive manner, or to drive units which are connected to earthed piping
systems in an electrically conductive manner.
To perform electrical installation dismantle the hood (è Fig. 1 1 ):
1. Unscrew the three mounting screws on the hood (è Fig. 1 2 ).
2. Carefully lift and remove the hood.
3. Route the electric cable through the cable connector (outside diameter
4.5 ... 10 mm) – tightening torque max. 3 Nm.
4. If required, use suitable wire end sleeves for flexible conductors.
5. Wire the socket strips according to the pin allocation – conductor cross section:
0.25 ... 0.5 [mm²] ; without wire end sleeve up to 0.75 mm²
The pin allocation depends on the type used.
Version for managing max. 3+1 solenoid valves and 3+1 sensors
The 24 V supply for the sensor S4 (pin 8, 9) and the 24 V supply for the solenoid
valve V4 (pin 10, 11) is provided via the operating voltage supply.
Pin allocation (spring force terminal 1 x 15 pin)
Signal
Switching input of PLC 24 VDC valve V1
Switching input of PLC 24 VDC valve V2
Switching input of PLC 24 VDC valve V3
Switching input of PLC 24 VDC valve V4
Output 24 VDC external valve V4
Output 0 V external valve V4
Power supply 0 V external sensor S4
Power supply 24 VDC external sensor S4
Signal input external sensor S4
Output sensor 4/LED yellow+green for PLC
Output sensor 3/LED yellow for PLC
Output sensor 1/LED green for PLC
Output sensor 2/LED red for PLC
Power supply 0 V DC
Power supply 24 V DC
Fig. 6 Version with max. 3+1 solenoid valves and 3+1 sensors
When connecting the sensors 1-3 (pin 4 ... 6):
• Take the max. permissible switching load of the sensors into account
(è Technical data).
When connecting an external sensor (sensor 4; pin 8 ... 10):
• Only use sensors with sufficient switching capacity (è Technical data).
Version for managing max. 2 solenoid valves and 2 sensors
Pin allocation (spring force terminal 1 x 6 pin)
Signal
Switching input of PLC 24 VDC valve V1
Switching input of PLC 24 VDC valve V2
Output sensor 1/LED green for PLC
Output sensor 2/LED red for PLC
Power supply 0 V
Power supply 24 VDC
Fig. 7 Version for managing max. 2 solenoid valves and 2 sensors

5.2 Pneumatic installation

Establish the necessary requirements for pneumatic installation:
– The compressed air supply is switched off.
– The compressed air lines are pressureless.
• Connect the C-TOP+ as follows:
1. If necessary, remove the self-adhesive labels from the supply ports.
2. Connect the C-TOP+ to the supply ports (è Fig. 1 7 ).
Connection
Printing
16
15
14
13
12
11
10
9
8
7
6
5
4
0 V 2
24 VDC 1
Connection
Printing
16
15
5
4
0 V 2
24 VDC
Connection Description
1
Supply port for operating pressure
3
Venting (integrated silencer)
Working port of solenoid valve V1 (è Fig. 1 5 ,V1)
A1
Working port of solenoid valve V2 (è Fig. 1 5 ,V2)
A2
1)
Working port of solenoid valve V3 (è Fig. 1 5 ,V3)
A3
Version with max. 3+1 solenoid valves and 3+1 sensors
1)
Fig. 8
Installing a tube:
• Press the tube into the tube coupling as far as possible.
Uninstalling a tube:
• Press and hold the locking ring of the fitting (e.g. by hand or by using the QSO
releasing tool from Festo) and pull out the tube.
• Seal any non-required fittings with blanking plugs.
6
Commissioning
Warning
Danger of crushing inside the sensor bracket (è Fig. 1 4). Reaching into the
sensor bracket can lead to a collision between your fingers and the actuator and
cause injuries.
• Do not reach inside the sensor bracket.
Setting the sensor position
You can generate the switching signals for the solenoid valves with the aid of a
master controller, or you can force the switching of the solenoid valves locally
using the manual override (MO).
There is a detenting MO on the side of the integrated solenoid valves (è Fig. 9 4).
It may only be activated using a blunt pin (max. 15 N).
4
3
1
Sensor S1 (output 1; green LED)
2
Sensor S2 (output 2; red LED)
3
Sensor S3 (output 3; yellow LED)
4
Manual overrides MO
5
Guide rail
Fig. 9
Sensor position (example)
To set the switching point:
1.
Switch on the compressed air supply.
2.
Switch on the operating voltage supply. The white LED lights up.
3.
Bring the process valve into the required position, using either the solenoid
valve's MO or the master controller.
Unscrew the clamping screw of the required sensor (Fig. 9 7).
4.
5.
Position the sensor half-way between the two switch-off points SME-8M: The
sensor LED goes out at the switch-off points. SMT-8M-A: The red sensor LED
goes out at the switch-off points, the yellow sensor LED stays illuminated. If a
sensor cannot be pushed adequately downwards, mount the sensor rotated
by 180° (cable outlet at the top).
6.
Tighten the clamping screw – tightening torque max. 0.6 Nm.
7.
If necessary, set the switching points of other sensors in the same way.
Tube outer diameter
8 mm
-
6 mm
6
1
2
5
6
6
Sensor – number and position
depend on the type used
7
Clamping screw for mounting the
sensor
7
7