Troubleshooting - General - Pentair Pool Products MiniMax CH Serie Manuel De Montage

Chauffe eau pour piscine et thalasso
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting - General

Possible Cause
Heater will not come on
Pump not running
Pump air locked
Filter dirty
Pump strainer clogged
Defective wiring or connection
Defective pressure switch
Defective gas controls
On-Off switch in "OFF" position
Heater Short Cycling
Insufficient water flow
Defective wiring
Defective flow valve or out of adjustment
Defective hi-limit and/or thermostat
Heater Makes Knocking Noises,
Make sure all valves on system are open
Heater operating after pump has shut off
Heater exchanger scaled
Please consult the latest edition of the "MiniMax
instructions. Repairs should only be attempted by properly trained service personnel.
P/N 472128
Remedy
Place pump in operation
Check for leaks
Clean filter
Clean strainer
Repair or replace wires
Replace switch
Call serviceperson
Turn switch to "ON"
(Rapid On and Off Operation)
Clean filter and pump strainer
Repair or replace wiring
Call serviceperson
Call serviceperson
Shut off gas supply and call serviceperson
Shut off gas supply and call serviceperson
CAUTION
®
Service Manual" for complete service and repair
18
Rev. E 11-5-07

Publicité

Table des Matières
loading

Table des Matières