10.2 WATER CONNECTION
Connect the water hose (table 1) to the water mains (fig.6).
The water mains must guarantee a minimum flow rate of
20l/min.
Otherwise a tank of suitable capacity (200 l) must be fitted with
clean water, to be kept full at all times, and from which water can
be taken by means of the self-priming pump supplied with the
machine. In this case the hose must have a minimum diameter of
3/4", a maximum length of 3m, preferably a foot filter and must not
be subject to deformation during use.
- Caution! The first time the water pump
is connected to the tank, it must be activated by manually
filling the intake line.
The same operation must be repeated each time the circuit
is drained, or after a prolonged period of disuse.
10.4 AIR CONNECTION
Connect the air hose to the machine panel and spray jet (fig.7)
11. START-UP
Close the air valve (ref.9a) supplying the spray jet (fig.10).
Open the micrometric valve (ref.8) virtually fully.
Turn the main switch/inverter (ref.1a) to position 1 or 2: in the
correct position the blue phase correct lamp illuminates (ref.1g).
Check that the water pressure gauge (ref.11) indicates a minimum
pressure of 3.5 bar and that the green no water pressure lamp
(ref.1i) is off. Otherwise, activate the pump by means of the
water pump switch (ref.1f). Press the water supplement
pushbutton (ref.1d) for 3-4 seconds.
Start the pump by means of the start pushbutton (ref.1c):
the lamp on the start/stop pushbutton illuminates and the mortar
pump starts up for a few seconds.
IMER INTERNATIONAL S.p.A.
FIG.6
1
FIG.7
KOINE 4/5
Open the spray jet air valve: the machine starts up. Check that
the water pressure does not fall below 2.5 bar; otherwise
activate the water pump. Use the micrometric valve to regulate
the water flow rate, displayed on the flow meter (ref.2) with
respect to:
- 800l/min if using gypsum based materials (pump D 6-3).
- 500l/min if using cement based materials (pump D 6-3).
Start the cell wheel by means of the relative switch (ref.1e) and
then stop it.
Close the air valve.
Fill the hopper with dry materials.
Open the air valve of the jet. Activate and deactivate the cell
wheel 3 or 4 times by means of the relative switch
(2 -3 seconds operation, 2-3 seconds stopped) and then switch
on permanently. Regulate the water to obtain the consistency as
recommended by the material manufacturer. Close the air valve
to the spray gun. Check the material hoses to ensure perfect
condition, that couplings are intact and the relative seals are
fitted, and pour approx. 3 litres of grout in the first section and
then connect them to the delivery manifold (ref.10) and spray jet.
Check that the cam levers ( A ) of the couplings have been
tightened correctly and that the seal
( B ) is fitted as shown in fig.8.
( A )
( B )
Start the machine: when the correct consistency of material is
delivered from the jet normal operation can be started.
The machine starts and stops by opening and closing the air
supply to the spray jet.
The machine is fitted with protection against power failure and
water pressure failure: if one of these occur, press the start
pushbutton to resume operation.
To stop the machine in the event of an emergency, press the red
emergency pushbutton (ref.1b) to shut down the machine - all
moving parts are shut down - and then turn the main switch to 0
and remove the electric power plug from the socket (ref.1l).
22
FIG.8
FIG.9