Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE. SAVE THESE INSTRUCTIONS.
WARNING:
Disconnect power during installation and before maintaining.
SAFETY:
This fixture must be wired in accordance with the Canadian Electrical Code, and
applicable local codes and ordinances.
Proper grounding is required to ensure personal safety.
A qualified electrician should perform all wiring.
PRODUCT SPECIFICATION
 Detection Method: Passive Infrared Sensor (PIR)
 Sensor Range: 32.8ft (10) x 180 degree spread (approx.)
 Time Adjustment: 5 seconds to 7 minutes (approx.)
 Power Source: 120VAC/60Hz, 32.50W
 With AC COB LED Chip: 2 pcs * 14W
 Load Rating: No extra Lights should be added to this unit
INSTALLATION & WIRING:
 Attach the crossbar to junction box using the mounting screws.
 Connect black wire (live wire) from the AC power to the single black wire from the fixture.
 Connect the white wire (common) from the AC power to the white wire from the fixture.
 Connect the ground wire from the power side to the green/yellow wire (ground) from the fixture.
 Make sure the polarity is correct.
 Attach the light to the crossbar screws and secure with the screw nuts.
 After installation, be sure to apply a bead of silicone compound all around backing where it meets
with the surface to ensure a weatherproof installation.
DO NOT MOUNT ON THE GROUND
Screw nut Silicone spacers
Fig. A
Mounting screw
Wire nut
Recommended height installation: 6.5' to 8.25'
Back plate screw
Cross bar
MS2HS-180
MS2HS-180

Publicité

loading

Sommaire des Matières pour RAB Design MS2HS-180

  • Page 1 MS2HS-180 INSTALLATION INSTRUCTIONS IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE. SAVE THESE INSTRUCTIONS. WARNING: Disconnect power during installation and before maintaining. SAFETY: This fixture must be wired in accordance with the Canadian Electrical Code, and applicable local codes and ordinances. Proper grounding is required to ensure personal safety.
  • Page 2  Adjust the lamp head to get desired light direction  Turn on electricity at fuse or circuit breaker box and verify success of installation  Apply silicone caulking (not included) around the perimeter of the fixture where it contacts the mounting surface for moisture seal MS2HS-180...
  • Page 3 MS2HS-180 INSTRUCTIONS D’INSTALLATION IMPORTANT: Lisez les instructions attentivement avant de tenter d’installer le luminaire. Conservez ces instructions. AVERTISSEMENT: Coupez l’alimentation électrique durant l’installation et avant d’effectuer une réparation. SÉCURITÉ: Ce luminaire doit être branché conformément au Code canadien de l’électricité, ainsi qu’aux codes et aux règlements locaux applicables.
  • Page 4 Mettez le courant au niveau du panneau des fusibles ou des disjoncteurs et vérifiez le succès de l'installation. Apposez un cordon de produit d'étanchéité à la silicone (non fourni) sur le pourtour du luminaire, là où il entre en contact avec la surface de montage, pour assurer l'étanchéité à l'eau. MS2HS-180...