Preparing for installation

OFF
Installation
Read the information in section "Safety instructions".
10 mm
6 mm
• Unscrew the cover lock screw (6) using the supplied hex key then lift the cover off.
• Use the four holes in the base (8) as a template to mark the wall mounting points.
• Drill the mounting holes using a ø6mm drill bit, then insert the plastic wall plugs (7) if
needed.
• Depending on the surface material, different screws and dowels may be required.
Switch the electricity supply, corresponding
circuit breaker and/or automatic fuse OFF.
Secure against unauthorized restart, e.g. by
installing a warning sign.
Check the power circuit for any remaining
voltage using an appropriate testing device.
• Remove the outer insulation on the wires to a
maximum length of about 16 mm.
• Strip the insulation on each of the three wires on the
mains cable to a length of about 6 mm.
• The protective earth cable (yellow-green) should be
at least 6 mm longer so that it remains the last cable
in the terminal strip in the event of a mishap.
IP65 Ingress protection warning. The
rubber cable gasket (3) should form a good
seal around the power supply lead to stop
moisture seeping into the junction box.
• Secure the base (8) to the wall using the four
mounting screws (5).
• Feed the mains cable through the gasket (3).
• Connect the 3 wires on the mains cable to the
3-pole screw terminal (brown wire= L/phase, blue
wire = N/neutral wire, yellow/green wire = PE/earth
wire/earth symbol
).
• Check the other screw connections on the terminal
strip and tighten them if necessary.
• Tighten the cable clamp (4) over the cable to prevent
it from being pulled out.
• Tidy any loose wires up, making sure they are all
contained within the junction box.
• Install the cover onto the base by first hooking in the two cover latches (1).
• Replace the cover lock screw (6) using the supplied hex key. Do not over tighten.
ON

Care and Cleaning

• Turn off mains voltage to the light (or disconnect it from the mains) and let it cool down
sufficiently.
• Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may
damage the casing or cause the product to malfunction.
• Use a dry, lint-free cloth to clean the product. To remove stubborn dirt, moisten the cloth
slightly with water.
• This product has an IP65 rating and can be sprayed clean using a fresh water hose.
• Never point a water jet, for example such of high-pressure cleaning equipment, at the lamp,
as that could damage the seals!
• Do not wear metallic or conductive jewelry such as necklaces, bracelets or rings when
carrying out maintenance work on the product (including cleaning).
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product in accordance
with applicable regulatory guidelines.
You thus fulfill your statutory obligations and contribute to the protection of the environment.

Technical Data

Operating voltage ......................... 220 – 240 V/AC, 50 Hz
Power consumption ...................... Max.8 W
Protection class ............................ I
Protection type .............................. IP65
Mounting location ......................... Outdoors
Illuminant ...................................... 48 LEDs
Dimmable ..................................... No
Colour temperature ....................... 3000 K (warm-white)
Luminous flux ............................... 130 lm
Operating/storage conditions ........ -20 to +70 °C, 0 – 100 % RH
Dimensions (L x W x H) ................ 220 x 79 x 220 mm
Weight .......................................... 1280 g
Distributed by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
These operating instructions are published by CEI Conrad Electronic International (HK) Limited, 18th Floor, Tower 2,
Nina Tower, No. 8 Yeung Uk Road, Tsuen Wan, New Territories, Hong Kong. All rights including translation reserved.
Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require
the prior written approval by the editor. Reprinting, also in part, is prohibited. The operating instructions reflect the current
technical specifications at time of print.
© Copyright 2018 by CEI Conrad Electronic International (HK) Limited
Turn the corresponding circuit breaker and/
or automatic fuse back ON
• If the light switch is on and the lamp does not light up,
turn OFF power to the circuit immediately.
• Turn OFF the circuit breaker and/or automatic fuse.
• Check the connection to the power circuit.