VOLTAGE DETECTOR
STRUCTURE
1. Disconnectable red test probe
2. Disconnectable black test lead with probe
3. LEDs for low voltage, and/or polarity indications
4. Tactile Barrier, protecting the user to prevent any accidental
contact with an naked conductor
5. Continuity test key
6. Phase rotation test key
7. " Ph " contact area
During live wire/neutral wire detection, you should touch this "
Ph " contact area with a nger to improve the tester's detection
sensitivity.
8. RCD test key
9. Green phase-rotation LED: clockwise
10. Red continuity indicator LED/phase-rotation LED:
anticlockwise
11. Dangerous-voltage LED ramp (red LEDs)
CHARACTERISTICS
Power Supply:
9V battery, 6F22 or equivalent, one piece
Buzzer:
Beeps for live wire identi cation. Emits continuous sound for the voltage > 5oV test and continuity
If there is no battery installed in the tester, the buzzer will not sound.
Operation Environment:
-10°C to 55°C, < 75%RH
Storage Environment:
-10°C to 55°C, < 85%RH
Altitude:
2000 meters
Size: 172><64><38mm (mainbody only)
Weight: About 18og (including battery)