Installation
Open the housing by loosening the screw under the button
cover and removing the upper side of the housing. Loosen
the three screws which connect the button and the
transmitter with the rear of the housing. Attach the rear side
of the housing to the desired position (ideally near the
entrance of residential units, in sleeping quarters or
underneath shop counters).
Insert the supplied 3 V lithium battery (size CR2477N).
Learning
1. Set the Secvest wireless alarm centre into learning
mode. Consult the instructions of the alarm centre for
more details.
2. Activate the tamper contact of the fire alarm button to
send a tamper message to the wireless alarm system.
The alarm centre recognises the button and immediately
allocates the "Fire" zone attribute.