Switches
S1
S2
Lamp default
Night Mode
ON
enabled
Forced
during day
Lamp default
Night Mode
OFF
disabled
Automated
during day
Leds
On during night
Blink at each flash
Power supply status
(1) - Only with cable end of 8mm length
(2) - Only with GPS option
(3) - OFC & OFC-CTR must be the same working voltage
Technical Data
OFC-CTR
48Vdc
Input Voltage
120 -240Vac
Consump�on
Max 10W (Controller only)
Cable size
- Ø 7 to 13mm
- Input : Up to 6mm²
Wire connexion
- Other : Up to 2.5 mm²
Fixa�on
- 4x hole Ø 6mm
- One per Lamp
Alarm
- System Power
- Luminosity Detec�on
OFC
(3)
Light available
OFI360 (240Vac Only)
Overview
S3
S4
Signal or
Power is on
antenna
during day
Ignored
Signal or
Power is off
antenna
during day
required
Indicator at each Lamp
On when light is ok
Dimensions
P/N
(1)
(2)
6
8
-
5
Fixa�on Assembly
22mm
2mm
10mm
Cabling
Lamp IN1
Lamp Earth
Lamp IN2
Lamp Relay COM
Lamp Relay NC
Lamp Ground
Lamp Synchro Signal
Lamp Day/Night Signal
Alarm Cabling
Normaly Open (NO)
Common (COM)
Normaly Closed (NC)
113176-048 113176-240
IN2
-48Vdc
Earth
Earth
IN1
+48Vdc
Neutral
Earth
Line

Publicité

loading

Sommaire des Matières pour obsta OFC-CTR

  • Page 1 Blink at each flash -48Vdc Neutral Earth Earth Earth Power supply status +48Vdc Line (1) - Only with cable end of 8mm length (2) - Only with GPS option (3) - OFC & OFC-CTR must be the same working voltage...
  • Page 2 Актуальную информацию смотрите на нашей WEB-странице. Změny v tomto dokumentu jsou možné bez předchozího upozornění. Aktuální informace najdete na naší webové stránce. 本文件的修改恕不另行通知。 OFC & OFC-CTR Cabling L810(F) & OFC-CTR Cabling OFC & OFC-CTR Cabling Naviblink & OFC-CTR Cabling 110-240Vac (or 48Vdc) 110-240Vac only ww.obsta.fr...