Fig. 4
Display for pro-
gramming
Arrow up
button
M-button
Arrow down
button
Programming
(See Fig. 4)
- The default settings for feed times F, F2 are 7:00 and 18:00 with a duration of 6
seconds each. The default settings for F3 and F4 are PM 12:00 with 0 seconds
running time. The entire duration can be adapted to your needs.
Set time
Press the " " or "↓" key until the correct time is displayed. Briefly press the " "
or "↓" key to step through the minutes, or press and hold to advance quickly.
Setting the feeding times
Press the "M" button. F will be displayed on the screen. Press the " " and "↓"
buttons to set the feeding time.
Set running time
After you have set the feeding time for F, press the "M" button again and release.
The digital clock shows the running time in seconds. The running time can be set
from 0 to 20 seconds.
A feed-amount guideline is shown in the following table:
Running time (second) 4
6
8
10
12
14
16
18
20
Ca, amount grams
360
450
590
730
860 1000 1090 1230 1360
Test run
Press and hold the "M" button for 10 seconds, the screen will show F0 and a
countdown of 10 seconds will be displayed on the screen. Attention when filled!
Immediately maintain a minimum distance of about 6 m from the feeder to ob-
serve the test cycle.