AMPLIFIER STATUS INDICATOR LIGHTS &
PROTECTION CIRCUITRY
There are two status indicator lights on the
control panel of the amplifier.
1) "Power" (Green): lights to indicate that the
amplifier is turned on and operating normally.
Located at the far left of the control panel.
2) "Protect" (Red): Indicates that the amplifier
protection circuitry has been activated
to prevent product failure due to thermal
overload, short-circuit or a dangerously
low impedance connected to the amplifier
outputs. Connecting the speaker outputs
to an impedance lower than 2 ohms stereo
(4 ohms bridged) will cause this protection
mode to activate. When this protection mode
is activated, the amplifier will shut down to
protect its circuitry. When the problem is
corrected, the amplifier will return to normal
operation and the "Protect" LED will shut off.
JX400/4D
SERVICING YOUR AMPLIFIER
If your amplifier fails or malfunctions, please
return it to your authorized JL Audio dealer so
that it may be sent in to JL Audio for service.
There are no user serviceable parts or fuses inside
the amplifier. The unique nature of the circuitry
in the JL Audio amplifiers requires specifically
trained service personnel. Do not attempt
to service the amplifier yourself or through
unauthorized repair facilities. This will not only
void the warranty, but may result in the creation
of more problems within the amplifier.
If you have any questions about the installation
or setup of the amplifier not covered in this manual,
please contact your dealer or technical support.
JL Audio Technical Support:
(954) 443-1100
9:00 AM – 5:30 PM (Eastern Time Zone)
Monday - Friday
11