1. Power tool
Symptom
Tool doesn't run
White smoke comes out
Tool suddenly stopped
Battery cannot be installed Attempting to install a battery other than
2. Charger
Problem
The charge indicator lamp
rapidly fl ickers purple, and
battery charging doesn't
begin.
The charge indicator lamp
blinks red, and battery
charging doesn't begin.
Battery usage time is short
even though the battery is
fully charged.
The battery takes a long
time to charge.
20
TROUBLESHOOTING GUIDE
Possible cause
No remaining battery power
The switch was at a position between I
and OFF (○) for a certain amount of time.
On fi rst use, the oils in the heat insulating
material may vaporize due to heating and
produce a small amount of white smoke.
The battery is overheated.
that specifi ed for the tool.
Possible Cause
The battery is not inserted all the way.
There is foreign matter in the battery
terminal or where the battery is attached.
The battery is not inserted all the way.
The battery is overheated.
The battery's life is depleted.
The temperature of the battery, the
charger, or the surrounding environment is
extremely low.
The charger's vents are blocked, causing
its internal components to overheat.
The cooling fan is not running.
Remedy
Charge the battery.
Set the switch to the OFF (○) position
once before moving it.
The smoke will stop after a few minutes of
continuous use.
Let the battery cool down.
Please install batteries that are multi volt
or BSL18xx series.
Possible Solution
Insert the battery fi rmly.
Remove the foreign matter.
Insert the battery fi rmly.
If left alone, the battery will automatically
begin charging if its temperature
decreases, but this may reduce battery
life. It is recommended that the battery be
cooled in a well-ventilated location away
from direct sunlight before charging it.
Replace the battery with a new one.
Charge the battery indoors or in another
warmer environment.
Avoid blocking the vents.
Contact a metabo HPT Authorized
Service Center for repairs.