WALL MOUNT LOW PROFILE
SPEAKER AND
SPEAKER/STROBE
ADDITIONAL CAN/ULC LISTED PRODUCT INFORMATION IS FOUND ON PAGE 4
MODELS
SPKSTR-24WLP*. . . . . . . . . . . . . . .
SPKSTR-24*-AL . . . . . . . . . . . . . . . .
CSPKSTR-24*-AL. . . . . . . . . . . . . . .
CSPKSTR-B*-AL . . . . . . . . . . . . . . .
CSPKSTR-G*-AL . . . . . . . . . . . . . . .
CSPKSTR-R*-AL . . . . . . . . . . . . . . .
CSPKSTR-24*-AL-WP . . . . . . . . . . .
CSPKSTR-B*-AL-WP . . . . . . . . . . . .
CSPKSTR-G*-AL-WP. . . . . . . . . . . .
CSPKSTR-R*-AL-WP . . . . . . . . . . . .
* Includes one or more of the following designators: P (plain - no text), R (red) or W (white)
I.
INTRODUCTION
The Potter Electric SPKSTR and CSPKSTR Series is a high quality speaker/strobe. The high intensity strobe utilizes a Xenon flash tube that generates a high-intensity flash visible from all angles.
The SPKSTR-24WLP and SPKSTR-24-AL is provided with a turn dial which allows for candela selection at the installation site; 15Cd, 30Cd, 60Cd, 75Cd, or 110Cd. The CSPKSTR-24-AL,
CSPKSTR-B-AL, CSPKSTR-G-AL, CSPKSTR-R-AL, CSPKSTR-24-AL-WP, CSPKSTR-B-AL-WP, CSPKSTR-G-AL-WP, CSPKSTR-R-AL-WP are fixed candela units, available in 15/75 candela
intensity only. This appliance is ideal for any occupancy that requires notification appliances per the applicable building or fire code or wherever dependable alarms are required.
The SPKSTR-24WLP and SPKSTR-24-AL speaker/strobe strobe is listed in compliance with ANSI/UL 1971, Signaling Appliances for the Hearing Impaired. The CSPKSTR-24-AL, CSPKSTR-B-AL,
CSPKSTR-G-AL, CSPKSTR-R-AL, CSPKSTR-24-AL-WP, CSPKSTR-B-AL-WP, CSPKSTR-G-AL-WP, CSPKSTR-R-AL-WP strobe is listed in compliance with ANSI/UL 1638, Visual Signaling
Appliances - Private Mode Emergency and General Signaling.
II. PRODUCT INFORMATION
The SPKSTR and CSPKSTR Series Series speaker/strobe offer a choice of field selectable power taps, 1/8, 1/4, 1/2, 1, 2 and 4 Watts for use with either 25VRMS or 70.7VRMS audio amplifiers.
The frequency range of the speakers is 400-4000Hz. All devices are suitable for line supervision. Speaker includes DC blocking capacitor which allows for supervision voltage of either polarity.
III. LOCATION
This appliance is intended for use in Fire Alarm Systems and is to be installed in accordance with this manual, the recommendation of the local authorities having jurisdiction, and other NFPA
documents that provide standards on notification appliances for protective signaling systems. The SPKSTR-24WLP, SPKSTR-24-AL, CSPKSTR-24-AL, CSPKSTR-B-AL, CSPKSTR-G-AL,
CSPKSTR-R-AL, are intended for indoor installations only; this appliance is not listed for outdoor or drip proof applications. The CSPKSTR-24-AL-WP, CSPKSTR-B-AL-WP, CSPKSTR-G-AL-WP,
CSPKSTR-R-AL-WP are intended for indoor or outdoor installations; this appliance is listed for outdoor or drip proof applications when used in conjunction with the SPKRBB back box.
Visual signal must be installed within 16 feet of the pillow when used in a sleeping area.
Visual signal must be in the direct viewing area of the occupant in order to be seen.
Visual signal can not be seen when objects such as doors, furniture or walls block visual signal.
NOTICE: VISUAL SIGNALS FOR THE HEARING IMPAIRED ARE ONLY ONE METHOD OF ALERTING THE HEARING
IMPAIRED. VISUAL SIGNALS MAY NOT BE THE PREFERRED METHOD FOR NOTIFYING ALL HEARING IMPAIRED
INDIVIDUALS.
NOTICE: THE VISUAL SIGNAL MUST BE SEEN BY THE SLEEPING PERSON. IF THE PERSON HAS HEAD TURNED OR
OTHERWISE UNABLE TO BE ALERTED BY VISUAL, THE VISUAL SIGNAL WILL NOT BE EFFECTIVE.
Visual Signal should NEVER be relied upon as the primary fire alert for the hearing impaired under these common sense conditions:
a. Sleeping face down on the bedding or pillow
b. Use of sleep medications of any kind
c. Use of alcoholic beverages or recreational drugs
d. Use of eye shades
e. If there are tendencies of deep sleep conditions
f. If a fire cuts power to AC circuits, the visual signal will not operate
g. If person is not within line of sight of visual signals
Under these and other similar common situations an alternate fire alert method such as a non-hearing impaired attendant is needed. The visual signal only increases the chance of being alerted
to the presence of fire. No system of this type can fully protect the hearing impaired in case of fire.
SPKSTR-24WLP SERIES
ANSI/UL AND CAN/ULC COMPLIANT
CSPKSTR-24-AL, CSPKSTR-B-AL, CSPKSTR-G-AL,
CSPKSTR-R-AL, CSPKSTR-24-AL-WP,
CSPKSTR-B-AL-WP, CSPKSTR-G-AL-WP,
CSPKSTR-R-AL-WP
ANSI/UL AND CAN/ULC COMPLIANT
WALL MOUNT SPEAKER WITH SELECTABLE STROBE
WALL MOUNT SPEAKER WITH SELECTABLE STROBE, ALERT TEXT
WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, AMBER LENS, ALERT TEXT
WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, BLUE LENS, ALERT TEXT
WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, GREEN LENS, ALERT TEXT
WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, RED LENS, ALERT TEXT
OUTDOOR WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, AMBER LENS, ALERT TEXT
OUTDOOR WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, BLUE LENS, ALERT TEXT
OUTDOOR WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, GREEN LENS, ALERT TEXT
OUTDOOR WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, RED LENS, ALERT TEXT
SPKSTR-24WLP AND SPKSTR-24-AL PRODUCT INFORMATION
550-0597
Page 1