ENGLISH
GB
Safety Instructions – Electrical Safety (UK only)
This appliance has been designed for dry vacuum cleaning only and must not be used
to pick up any liquids. Kerstar declines any liability should this or any of the following measures
not be observed.
Prima & Prima CD
These models are double Insulated Class 2 appliances and have 10 metres of 3-core fl ex with a moulded-
on, impact resistant 13 amp 3-pin plug (to BS1363A). The fuse fi tted (ASTA Approved) is rated at 13
amps. Only 13 amp fuses must be used. Note: Fuses do not give personal protection against electric
shock.
KV10/1 & KV15/1
These models are Earthed Class 1 appliances and have 10 metres of 3-core fl ex with a moulded-on,
impact resistant 13 amp 3-pin plug (to BS1363A). The fuse fi tted (ASTA Approved) is rated at 13 amps.
Only 13 amp fuses must be used. Note: Fuses do not give personal protection against electric shock.
Should the moulded-on plug be damaged please follow this procedure:
Switch off supply at socket, remove damaged plug from socket, cut plug off fl ex.
Make sure the damaged plug is disposed of immediately so as there is no chance of the damaged
plug being used.
Fitting a Replacement Plug
Use only a 13 amp (approved) plug. To fi t proceed as follows:
1)
Ensure that the lengths of wire to be fi tted inside the
plug have been cut to the correct length and the ends
correctly prepared. When preparing the cable ends take
care not to damage the outer sheath, or the insulation
surrounding the inner conductors.
2)
Connect the blue (NEUTRAL) wire to the terminal in
the plug which is marked with the letter "N" or coloured
black.
3)
Connect the brown (LIVE) wire to the terminal in the
plug which is marked with the letter "L" or coloured
red.
4)
Connect the green/yellow (EARTH) wire to the
terminal in the plug which is marked with the letter
"E" or coloured green (KV10/1 & KV15/1 only).
5)
Tighten all screws. Ensure that all conductor strands have entered into the terminal posts and that
the mains lead is securely held in place by the cable clamp.
6)
Ensure that the plug is fi tted with a 13 amp ASTA approved BS1362 fuse. Replace the top cover
of the plug and secure.
4