INSTALLATION RECOMMENDATIONS

Installation of the filter assembly below the water level of the pool is highly recommended. In the event that
the filter is installed above the pool water level, a check valve, accessible through a service hatch, must
be installed on the suction line.
Allow a surface area of 1200 mm x 1200 mm for the installation.
Position the control panel as close as possible to the multiport valve to facilitate manipulations.
To prevent vibrations, and any resonance effect, insert a sheet of soft rubber between the base of the
pump and the ground.
1.1

Standard installation

A - B :
Skimmer
C :
Main drain
D :
Vacuum point
E :
Return fitting
F :
Waste
G :
Valve
16/36
2021/01 - Indice de révision : F - Code : 26730