Operating Instructions
MaxLite Slim Downlight Baffle Style
®
General Wiring Diagram
CAUTION: Turn off electrical power at fuse
or circuit breaker box before wiring fixture
to the power supply.
Input Rating: 120V, 60hz, Triac dimming
Black = Line
White = Neutral
Green = Ground
Installation Instructions
NOTE: For wet location installation, after fixture is installed on
ceiling, put silicone glue to seal the gap between fixture and
ceiling.
1.) Make sure the POWER IS TURNED OFF from the electrical
panel before starting installation or maintenance.
2.) Locate a suitable position to place the fixture and open a hole
in accordance to the cut-hole dimensions (refer to cut-hole
template for appropriate size.)
3.) Run the electrical wire from the switch (power supply),
through the mounting hole.
4.) Open the hardware box swing cover and remove the
appropriate knockouts.
5.) Insert the electrical supply cable through the knockout.
6.) Wire box using supplied quick connect push-in terminals.
- Connect green ground wire of cable to green wire
on box.
- Connect black wire of cable to black wire of box. (Fig. 1)
- Connect white wire of cable to white wire of box.
7.) Place all wiring and connections back into the box and close
into ceiling. (Fig. 2)
the cover. For remodel applications, insert the junction box
8.) Use the CCT switch on the connector cable to select
2700K, 3000K, 3500K, 4000K or 5000K. (Fig. 3)
9.) Push the spring loaded clips on the fixture upwards and
insert fixture base into the mounting hole. Release the clips
and the fixture will be pulled flush to the ceiling. For airtight
ceiling (Fig. 4)
installations, install the foam gasket between the fixture and
10.) Once assembly is complete, turn on power to confirm the
fixture is working properly.
© Copyright 2020. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006 Tel: 973-244-7300 Fax: 973-244-7333 Email: info@maxlite.com
(+) LINE
(-) COMMON
GROUND
SDB Series
BLACK
Light
WHITE
Fixture
GREEN
CCT Tunable Switch
27K 30K 35K 40K 50K