(EN) ENGLISH
CORE rechargeable battery for TIKKA
Li-Ion rechargeable battery, compatible with the TIKKA
headlamps.
Capacity: 900 mAh.
Recharge your battery with a USB 5 V output charger.
Charge it completely before first use.
The Li-Ion battery loses 10 % of its capacity per year. It can be
recharged 300 times (after 300 times, it will still have 70 % of its
original capacity).
Use the battery at temperatures between -30° C and +60° C.
Electromagnetic compatibility
Conforms to the requirements of the 89/336/CEE directive on
electromagnetic compatibility.
Warning, an avalanche beacon in receive (find) mode can experience
interference when in proximity to your CORE battery. In case of
interference (indicated by static noise from the beacon), move the
beacon away from the rechargeable battery.
Nomenclature of parts
(1) Energy gauge, (2) Battery contacts, (3) USB A/micro B cable,
(4) USB micro B port.
Charging the battery
Recharge only with a USB 5 V charger, for example:
- Computers (they must be turned on and in use).
- Solar panels with a USB 5 V output (preferably panels delivering at
least 5 W or 1 A for faster charging).
- PETZL CORE E93110 charger (allows charging from 110-220 V wall
socket or car cigar-lighter socket).
You can charge your battery separately from the lamp.
Warning
Recharge only with a USB A/micro B cable. The charger's
output voltage must not exceed 5 V. Never recharge using the
battery contacts: risk of explosion and/or fire.
Charge time is three hours. The charge time can be longer if the
power delivered by the charger is insufficient.
During charging, one of the energy gauge's three bars blinks every
second. The color of the blinking bar indicates the battery's charge
level:
- Red: Battery charged 0 to 33 %.
- Orange: Battery charged 33 to 66 %.
- Green: Battery charged 66 to 100 %.
When charging is complete, the green bar on the energy gauge is
constantly lit.
If the blinking is slower (every three seconds), this means that the
power delivered by the charger is insufficient; the charge time will
be longer.
- Batteries should always be charged at a temperature between 0 °C
and 40 °C to avoid battery deterioration.
Charging indicator
You can verify the battery charge level by turning on your lamp. One
of the energy gauge bars is constantly lit:
- green bar: battery charged 66 to 100 %.
- orange bar: battery charged 33 to 66 %.
- red bar: battery charged 20 to 33 %.
When the red bar is blinking (battery charged 0 to 20 %), the battery
should be recharged. The lamp will also blink as a reminder to
recharge.
Attention: if you use your TIKKA PLUS, ZIPKA PLUS or TIKKA XP
lamp with the CORE rechargeable battery, the battery charge
indicator on your lamp is no longer valid.
Lighting performance - battery life
See lighting performance table for the different lamps.
Initially, your CORE rechargeable battery is programmed in non-
regulated mode.
By downloading the OS by Petzl software from our site at www.petzl.
com/CORE, you can:
- change the operating mode of your battery (regulated/non
regulated,
- change the power delivered by the battery and thus change the
battery life of your lamp.
Battery life diminishes markedly below 0 °C.
Precautions
Device not recommended for children
WARNING, incorrect use can damage the battery.
- Do not unplug the USB cable from the computer when you are
using the OS by Petzl software.
- Do not submerge the battery in water.
- Do not put the battery in a fire.
- Do not destroy the battery, it can explode or release toxic materials.
If your device is damaged, do not dismantle it or change its structure.
Retire your battery if its casing is broken or cracked.
In case of malfunction
Inspect the battery contacts for corrosion. If corroded, gently scrape
the contacts clean without deforming them. Check the USB A/micro B
cable connections.
If your battery still does not work, contact Petzl.
Maintenance
If used in a damp environment, remove the battery from the lamp
and dry it, leaving the lamp and USB port cover open. If your battery
comes into contact with sea water, rinse with fresh water and dry it
with the lamp open.
3
E93100 ACCU CORE
E935100E (100212)
Storage, transport
It is preferable to carry your battery in the lamp, and take care to
range
2
store it in a dry place at temperatures between -20° C and 40° C.
Before long-term storage, it is preferable to recharge the battery to
range of
2
50 % (repeat this step every two months).
Protecting the environment
Lamps and batteries should be recycled. Do not throw them in
the regular trash. Dispose of these items by recycling them in
accordance with applicable local regulations. By doing so you play a
part in protecting the environment and public health.
The PETZL guarantee
This product is guaranteed for 3 years against any faults in materials
or manufacture. Exclusions from the guarantee: more than 300 usage
cycles, oxidation, normal wear and tear, modifications or alterations,
incorrect storage, poor maintenance, damage due to accidents, to
negligence, or to improper or incorrect usage.
Responsibility
PETZL is not responsible for the consequences, direct, indirect or
accidental, or any other type of damage befalling or resulting from
the use of its products.