OPERATION

SPLASHING OR IMMERSING OPEN
WARNING
DRIP PROOF MOTORS IN FLUIDS
Hazardous
voltage
CAN SHORT OUT MOTOR AND
CAUSE FIRE, SHOCK, BURNS OR
DEATH.
NOTICE: PUMP MUST BE FULLY PRIMED BEFORE
OPERATION. DO NOT RUN PUMP DRY.
After stabilizing the system at normal operating condi-
tions, check the piping. If necessary, adjust the pipe
supports.
Do not run pump dry; damage to me-
CAUTION
chanical seal will result. Do not run against
closed nozzle for prolonged periods or damage to pump
and piping will result.
HANDLE ASSEMBLY
Remove two top bolts from motor adapter. Insert them
through handle back into the motor adapter and tighten
securely.
NOZZLING
It is important to choose the right nozzle for proper
pump performance. The faucet supplying the water to
the pump should be checked to see what rate of flow it
will furnish. If the one min. flow with the faucet open is:
7 gals. — Use 6 gpm nozzle V005
(which is included with each AM)
6 gals. — Use 5 gpm nozzle V150
5 gals. — Use 4 gpm nozzle SN0045
4 gals. — Use 3 gpm nozzle V1015
By using this method of choosing nozzles we can keep a
positive pressure at the pump intake. This will keep the
pump from "robbing" water from other faucets.
DAIRY FARM USE
We recommend that all WaterGuns
producing Grade "A'' milk be equipped with a Vacuum
Breaker, installed according to instructions supplied with
Vacuum Breaker. This prevents sub-atmospheric pres-
sure in the supply line even if the water supply should
diminish. We suggest the WaterGun be hung on a wall at
least 18" off the floor and that a hose rack be provided to
store the discharge hose off the floor.

MAINTENANCE

FAILURE TO DISCONNECT AND
WARNING
LOCKOUT ELECTRICAL POWER
Hazardous
voltage
BEFORE ATTEMPTING ANY
MAINTENANCE CAN CAUSE SHOCK,
BURNS OR DEATH.
Motors have permanently lubricated bearings. No
lubrication is possible or necessary. Follow the motor
manufacturer's recommendations for maintenance.
4
AM 7 Kit
®
used on farms
To REMOVE pump from service drain all pumpage
from pump and piping.
To RETURN pump to service replace all plugs and pip-
ing using Teflon™ tape or equivalent on male threads.
• Refer to "OPERATION" section of manual.

DISASSEMBLY

Place wrenches on adapter (13) and discharge head (1),
and unscrew discharge head and casing (3).
NOTE: CASING HAS A LEFT HAND THREAD
ON BOTH ENDS AND IS SEALED WITH
O-RINGS ().
Remove klip ring (6) from end of shaft (11). The
stages, each comprising a bowl (9), impeller (8) and
diffuser (7) may now be removed. If pump has been
clogged by foreign matter, but otherwise undamaged,
further dismantling may be unnecessary. If shaft assem-
bly (11), shaft seal (1) or motor are to be replaced,
proceed as follows:
Remove plug (18) from rear of motor and hold
motor shaft with screwdriver. Unscrew pump shaft
coupling assembly (11) from motor shaft. Remove
four motor mounting bolts (14), separate the motor
from frame by withdrawing it straight back.
Motor may have to be pried with two screwdrivers
if the shaft seal sticks. The shaft seal stationary seat
may be pushed out of adapter from the motor side.
There is a rubber coupling o-ring (19) between motor
shaft and coupling which will usually remain on the
motor shaft as the seal is pulled over it.

REASSEMBLY

Check that the rubber deflector (0) and the coupling
o-ring (19) are on the motor shaft. If they are worn or
damaged, replace. Install stationary seal seat in frame
(13) and mount frame (13) and handle (15) to motor.
Install seal rotating element, making sure faces are clean
and that the last rubber member goes over the coupling
o-ring and onto the motor shaft. Screw the pump shaft
and coupling assembly (11) on until it seats up against
the motor shaft. With a straight edge across the face of
the frame check the location of the outboard end of the
coupling. Due to variations in motor shaft length, etc., it
will be from .030" short to flush. Add .010" shims 7K155
until they are flush or higher, i.e., the last shim interferes
with the straight edge. Put the required stages on check-
ing each stage for additional shim requirements by put-
ting the straight edge across the bowl and checking the
location of the impeller hub. After all the stages are on
the shaft replace klip ring (6).
Check o-ring on both frame and discharge head and
replace if damaged. Install casing (3) and bearing spider
(4). Thread on discharge head (1) (Notice: left hand
threads) and tighten.