Note:
Mains connection leads must be flexible polychloroprene-coated cables. All the
cables installed inside the cabin must be capable of withstanding temperatures
of at least 140°C. Heat-resistant silicon cables must be used.
Description of the vaporizer parts
1 Front cover
2 Humidity/temperature sensor
3 Vaporizer tank
4 Vaporizer grating with tray
5 Integrated control unit
6 Mains power input with 230V ~ power plug
7 Raised floor with contact
8 Base mount for vaporizer tank
9 Reset button (below type plate)
10 Hot plate
CAUTION! RISK OF SCALDING!
Steam will be discharged from the top when the vaporizer is operating. There
is a risk of scalding in the area around the steam discharge point.
• Leave the vaporizer tank in the mount provided as a general rule.
• Remove the tank for filling and / or cleaning only.
• Never operate the unit without water. The vaporizer may develop a defect if
operated without water.
• Only use water that meets the quality requirements for domestic water.
• Hard water and water containing iron will leave residue on the stones, metal
surfaces and in the water tank.
• Add herbal sachets and fill the vaporizer tray before starting the unit. Switch
off the unit to refill the vaporizer tray!
• Do not pour sauna infusions straight into the vaporizer tank. Additives in the
evaporator tank tend to bubble up and boil over. Refer to the manufacturers'
instructions.
• Do not fill the tank above the maximum mark.
• The empty tank has a capacity of approximately 3 liters. This quantity is
adequate for around 90 minutes of continuous operation (depending on the
amount of limescale on the hot plate).
• Never immerse the tank in water.
• Do not put the vaporizer tank in the dishwasher.
• Never pour water into the mount for the vaporizer tank.
• Do not operate the vaporizer without the grating - risk of scalding!
• Beware of hot water spilling over the edge.
• Do not mix alcoholic drinks to make infusions and do not use other additives
not intended for use in saunas as they pose a fire, explosion and health
hazard.
• After every steam session, allow the unit to cool, remove all the remaining
water and clean the tank.
• Failure to follow the above instructions will invalidate the warranty!
Removing/replacing the vaporizer for filling and cleaning
The vaporizer can be removed from the mount and refitted. Do not fill the tank
above the maximum mark. Never immerse the tank in water. Make sure that
the base mount with the connecting contacts is kept dry at all times.
If the base gets wet:
Switch off and unplug the vaporizer, then use an absorbent cloth to dry the
base and the surface below the base.
The vaporizer is controlled by an internal control unit with a humidity and
temperature sensor.
Switching on:
Press the▲ON button for 2 seconds. All the LEDs will light up briefly and the
unit will be on for 4 hours. The 10% LED lights up = control point setting - the
LED for the relevant humidity range will flash.
Setting the temperature:
Press▲On to increase the target humidity in 10% increments. The unit will not
generate steam while the humidity level is below the setting.
Reducing the humidity:
Press▼OFF to reduce the target humidity in 10% increments. If the target
humidity is below the actual humidity, the vaporizer will cut out until the actual
humidity is below the target humidity again.
If a humidity level is set, the vaporizer operates automatically depending on
the cabin temperature and humidity.
The target humidity LED lights up, the actual humidity LED flashes.
It will flash if the actual humidity reaches the control point setting.
The vaporizer can only operate in the permitted humidity range (droplet
symbol as seen in diagram 9/10).
If the cabin temperature is higher than the permissible humidity level (grey
area in diagram 9/10), the LED will flash rapidly and steam will be generated
until the maximum permissible humidity is reached.
If the cabin temperature exceeds 85°C for 10 minutes, the entire unit will cut
out.
Switching off the control unit:
Press▼OFF for 2 seconds. All LEDs light up briefly and the unit switches off.