Smart HOLD
The meter will beep continuously and the display will flash
if the measured signal is larger than the display reading by
50 counts. (However, it cannot detect across the AC and DC
Voltage /Current).
VoltSense
Keep the VoltSense button down to activate the VoltSense
function.
Caution
The number of dashes displaying on the display indicates the
electric field intensity. If no indication, voltage could still be
present. Always verify with leads.
12