Télécharger Imprimer la page

SwissPhone LGRA Expert Mode D'emploi page 7

Publicité

Battery/rechargeable battery recognition
After a battery/rechargeable battery has been inserted, the
battery recognition and receiver start-up procedure begins.
You will hear a beep when the procedure ends.
If a newly inserted battery is very weak, the receiver will not
recognize immediately whether a dry cell or rechargeable
battery has been inserted. The receiver will assume that a
rechargeable battery has been inserted and charging will
start automatically. The receiver will then measure the
battery voltage. When the threshold voltage has been
reached, the battery recognition and receiver start-up
procedure is activated. The battery is recognized and the
relevant information is stored in the receiver. If a recharge-
able battery has been inserted, charging will continue. If it is
a dry cell battery, charging will stop.
The recognition can take up to ten minutes. During this time
the battery will be charged.
Some types of receiver offer manual selection of "Recharge-
able/dry cell battery".
Please refer to the receiver manual for further information.
Relay contact configuration for the (A)LGRA Expert
There is an isolated relay contact to audio socket pins one
and three. The switching capacity at the socket is: 30 V, 1 A
AC/30 V, 1 A DC.
Please note that there is no plate on the (A)LGRA to show
the relay contact configuration.
REL 41
30 V, 1 A AC
30 V, 1 A DC
3
5 2 4
If there is a power failure, the relay contact will close if all calls
have not been acknowledged by the receiver. If a call is re-
ceived while in the charger and a power failure occurs,
contact is activated again as soon as power returns.
Notes
This charger is suitable for the recommended power sources.
It includes a charging protection for dry cell batteries. Please
adhere to the stated connection values for the DIN socket.
Please use the charger in a dry place only.
The device complies with Part 15 of the FCC Rules. Operation is
subject to the condition that this device does not cause harmful
interference.
R&TTE 99/05/EG (for radio and telecommunications installations).
Please ask for a declaration of conformity at info@swissphone.com.
1
5VDC (max. 400 mA)
(4 – 7 VDC / 25 mA)

Publicité

loading

Ce manuel est également adapté pour:

Algra expert