3
Config-
Digital input – Connect to pin
urable
1 to activate, or leave floating
6
(Input or
(unconnected) to deactivate.
Output)
Digital output – Connected
to pin 1 when activated,
floating (unconnected) when
deactivated. If used with an
inductive load, e.g. a relay,
a diode must be connected
in parallel with the load, for
protection against voltage
transients.
12 V
max 50 mA
G
1
2
3
4
D
S
17
AXIS F44 Main Unit
0 to max 30 V DC
0 to max 30 V DC,
open drain,
100 mA