Troubleshooting
Problem
Possible cause
Motor does not run
No power supply
Defective cable
Motor is growling,
Gear ring is blocked
running but not
starting
Defective condenser
Mixer gets blocked
The extension cable does not
by small loads,
meet the requirements
switches off auto-
matically
Contact pressure on
The pressure spring is not
the hand wheel is too
sufficiently tight
loose
Drum is not rotating
Defective V-Belt or mismatch-
after starting
ing voltage
Solution
Make sure the voltage meets the re-
quirements stated in the technical data
Deliver the machine to a recognised
workshop for repairing
Clean the ring gear
Deliver the machine to a recognised
workshop for repairing
Required cross section area for exten-
sion cables:
1.5 mm2 - up to 25 m
2.5 mm2 - longer cables
Tighten the screw (page IX)
Make sure the voltage meets the re-
quirements stated in the technical data
Deliver the machine to a recognised
workshop for changing the V-Belt
EN
87