ASSEMBLY AND INSTALLATION INSTRUCTIONS Continued
Insulated Class "A"
Chimney System
Single Wall Chimney Adapter
Slip Connector. Sheet
Metal Screw to Chimney
Connector.
Middle Pipe Section Bottom
Fits Into Damper Section
Damper Pipe Bottom Fits
Into Unit
The above illustration represents the installation procedure for dripless pipe installation. This installation method of installing the
connector pipe with the male end down allows for any moisture to remain on the inside of the connector pipe.
The Malm Connector Pipe is made of 22 guage steel. The pipe is designed to fi t tightly together and does not require screws or
fastners between the pipe sections. Only the slip pipe requires screws to connect to the single wall chimney adapter.
At fi rst glance you may become concerned that smoke will escape the pipe and enter the room. This is not how the system will
work. The vacuum in the chimney system will always pull air into the chimney. If you experience a downdraft with your installa-
tion it indicates that additional chimney height or a specialty draft cap be added to your chimney system. Contact your dealer for
further information regarding downdrafts.
Material List
Included with the Lancer is the following:
Unit
1 - 7 x 24 damper pipe
1 - 7 x 24 pipe section
1 - 7x 24 slip section pipe
4 - 6lb bags of Malmcrete refractory.
Lancer - Page 5
Insulated Pipe
Support Box
Ceiling
Sheet Metal
Screw
Slip Connector
DuraVent 7DBK-ADSL or 8778 Adapter
ICC Excel Flue Extension (7EX)
Selkirk Stovepipe Adaptor
Or Single Wall Chimney Adapter
DuraVent
8778
ICC Excel
7EX
It is not necessary or required to screw the pipes
together. The pipes are designed to fi t tightly
together.
Do not attempt to screw the porcelain enamel
coated pipes together.