B- Securing the base using the peg
The Virax support stands are provided with 2 types of peg:
Peg for concrete;
Cannot be reused
If the slot cap is fixed and there is a vacuum clamp base seal under the support
stand you must remove them. To remove the slot cap:
1 – Loosen and remove the socket head screw.
2 – Remove the slot cap and its seal from the base.
3 – Mark the position of the attachment hole to be
drilled.
4 – Drill the hole (Ø 15) to a depth of 50 mm (A). Y
insert the M12 peg (B) and push it in using the insertion
tool (C).
5 – Insert the quick tightening screw (D) into the peg.
6 – Position the support stand then fix the washer (E)
and the attachment nut (F) to the quick tightening
screw (D)
7 – Tighten the nut (F) using an SW 27 wrench
8 – Before and after you tighten the nut (F), adjust
the 4 stop screws to adjust the surface.
You must check that the support is solidly
secured.
Peg for breeze block, etc.;
Can be reused
18
-EN-