TROUBLESHOOTING

PROBLEM
Charger doesn't work. Charger
shows defective mode (LED
flashes Red).
Charger doesn't work. Charger
shows evaluation mode (LED
indicates Red solid ON).
CAUSE
Battery pack or charger is
defective or there is a bad
connection between the battery
pack and charger.
Battery pack is either too hot, or
too cold.
11
11
SOLUTION
1. Try to remove and reinsert
the battery pack in the charger.
2. Try charging a different
battery pack.
3. Unplug the charger and wait
until the red LED goes out, then
reconnect the plug to the power
supply.
Allow the battery pack to
reach normal temperature.
Charging will begin when
battery pack returns to 3°C-47°C
(37°F-117°F).