Velbus VMBKP Mode D'emploi page 22

Masquer les pouces Voir aussi pour VMBKP:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Quick Programming Summary Chart
(for the full version, see the VMBKP User Manual on www.velbus.eu)
LOCATION
FUNCTION
01
Master Code
User Codes/Cards for
10
User Group 1
User Codes/Cards for
20
User Group 2
40
Visitor Codes
Personal Safety &
60
Lock-Up
Notification Tone ON-
71
OFF
Channel status
72
announcer ON-OFF
73
Standby LED flashing
SYSTEM CODE
FUNCTION
MASTER CODE
Factory set Master Code (to set keypad in
programming mode).
0 0 0 0
THIS IS NOT A PERMANENT SYSTEM CODE, IT
NO LONGER EXISTS WHEN A NEW MASTER
CODE IS PROGRAMMED BY THE USER.
REFRESH CODE
9 9 9 9
Refresh the system and set all parameters
back to default values (except Master Code).
DAP CODE
Direct Access to Programming code. Valid only
2 8 2 8
during the power-up delay period (1 min. after
power-up).
CLEAR USER CODES/CARDS FOR THE SELECTED
LOCATION
LOCATIONS:
0 9 9 9
10: User Group 1
20: User Group 2
40: Visitor Group
41: Duress Group 1
42: Duress Group 2
* *
EXIT PROGRAMMING CODE
Velbus – Legen Heirweg 33, BE-9890 Gavere, Belgium – tel. +32 9 384 36 11 – e-mail: info@velbus.eu – www.velbus.eu
ENTRY LIMITS CODE OPTIONS
4-8 digits
CODE 1: MEDIA
1: EM Card
2: Private User Code
3: EM Card + Secondary User Code
4: EM Card + Common User Code
5: Deletion of User Code
CODE 2: USER ID
000-999: Group 1 (location 10)
001-100: Group 2 (location 20)
CODE 3: USER CODES/CARDS
4-8 Digits or Read EM Card
CODE 1: VISITOR ID
01-50
CODE 2: VALID PERIOD
00: One time
01-99 hours
CODE 3: Visitor Code
4-8 digits
LOCK-UP CODE
1: after 10 trials, lock-up 60s
2: after 10 trials, activate duress
output
5-10: after 5-10 trials, lock-up 15
minutes
00: no lock-up
MODE
0: OFF
1: ON
MODE
0: Notification
1: Beep 1s
2: 2 short beeps
MODE
0: OFF
1: ON
CODE ENTRY
0 1 MASTER CODE #
1 0 CODE 1 CODE 2 CODE 3
#
2 0
CODE 1 CODE 2 CODE 3
#
4 0
CODE 1 CODE 2 CODE 3
#
6 0
LOCK-UP CODE #
7 1
MODE #
7 2
MODE #
7 3
MODE #
CODE ENTRY
0 0 0 0
*
*
OR
NEW MASTER CODE
*
*
9 9 9 9
#
2 8 2 8
#
LOCATION
0 9 9 9
#
* *
VMBKP
FACTORY DEFAULT
NIL
NIL
NIL
NIL
1 (60s lock-up after
10 trials)
1 (ON)
1 (Beep 1s)
1 (ON)
RESULTS
System in Programming Mode
All programmed data are
cleared & all values are reset to
default values except the
Master Code.
System in Programming Mode
Whole group of users cleared
for the selected location
System back to normal
operation after programming
VMBKP-ed1

Publicité

Table des Matières
loading

Table des Matières