Troubleshooting - ALFRA AHP-M Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting

Maintenance, testing and repair work may only be carried out by qualified electricians according to the regulations
valid in the respective country.
Error
The main switch does not
light up when the pump is
switched on.
The motor does not start
or move.
The electric motor rotates
just slightly or does not
deliver full power.
18
All manuals and user guides at all-guides.com
Control
Check the power supply
and the mains.
Is the commanding feed of
the tool connected?
Did you choose a suitable
tool and the correct
control?
Did you choose a suitable
hand or foot switch?
Did the electrical fuse
protection of the power
supply trigger?
Does the PCB work
properly? Is the mains
voltage applied to the
motor cable or the motor
terminal box?
Is it possible to move the
motor fan?
Be sure to disconnect the
pump from the mains.
The contactor is not
energized.
The starting current
limitation is defective on
the side of the motor or is
not conducting anymore
(approx. 5 Ohm resistance
at 25°C body temperature
of the IRC thermistors).
Is an extension cable or
cable reel used to connect
the pump to the power
supply?
Cause
The mains is not or not
correctly plugged in.
Cable break or damaged
mains.
The fuse has triggered
due to fault current.
The commanding feed is
not or not correctly
plugged in.
The pin assignment and
the tool buttons must
match the pump.
The pin assignment and
the tool buttons must
match the pump.
The power supply is not
sufficient to the max.
current demand of the
electric motor.
The electrical fuse
protection is not
dimensioned sufficiently.
The PCB is defective or
incorrectly connected.
The motor is mechanically
blocked due to overload,
contamination or foreign
matter.
The contactor is defective,
the connections are burnt.
The IRC thermistor is
defective due to overload
or wear.
The cable is not unrolled
completely.
Conduction loss
(electrical resistance too
high)
Repair
Have the electrical
connection checked and
repaired by
a qualified electrician.
Have the electrical
connection checked and
repaired by
a qualified electrician.
Chose a compatible tool
or consult with the
manufacturer.
Chose a compatible hand
or foot switch or consult
with the manufacturer.
Connect the motor to a
suitable power supply.
Use another protection,
circuit breaker 16A type B
Have the electrical
connection checked and
repaired by
a qualified electrician.
Replace the component or
have the pump repaired
by the distributor or
manufacturer.
Replace the component or
have the pump repaired
by the distributor or
manufacturer.
Replace the component or
have the pump repaired
by the distributor or
manufacturer.
Replace the component or
have the pump repaired
by the distributor or
manufacturer.
Unroll the cable
completely.
Use a shorter extension
cable or a cable with a
higher cable cross-
section.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

0385523189

Table des Matières