Accessories Supplied; Instructions For Requesting Assistance And Replacement Parts; Installation; Connection To Wall - Ferroli O100 Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1.5 Accessories supplied

The supply includes:
-
two male connectors for powerline communication bus;
installation, use and maintenance manual.
-

1.6 Instructions for requesting assistance and replacement parts

To request any assistance and/or replacement parts contact your dealer, area importer or the nearest authorized service center, clearly
specifying the following: remotable display model (i.e. UTILITY), date of purchase, list of replacement parts and details of faults or malfunctioning.
Consult the website www.colastufe.com to find the nearest service center.
- Operations on components must be carried out by authorized and/or qualified personnel.
- Make sure all electrical connections are disconnected before carrying out any operation.
- Only use original replacement parts.

2 INSTALLATION

2.1 Connection to wall

The UTILITY display is suitable for operation in a domestic environment. It already has holes for wall mounting.
2
Run a cable (2 x 0.5 mm
shielded) from the terminal on the control board of the proprietary heating unit directly to the wall box, where the
UTILITY display will be fitted. To locate the connector of the compatible control boards see par. 2.3.
The maximum length of the connection cable is 100 m.
- Installation must be carried out by qualified and/or authorized personnel.
- The terminal is polarized, therefore invert the connection of the wires if the UTILITY display does not switch on.
Every installation must ensure a technical space for the insertion of a USB pen drive in the side slot for possible firmware upgrades.
The UTILITY display has its own ambient sensor, for detecting a temperature separate from that read by the stove. It is up to the specialized
technician to set your preference regarding temperature detection, consulting the "installer menu" section in the manual of the heating device.
In case of no "installer menu" section, contact an authorized service center.

2.2 UTILITY display PCB

Indicated below by an arrow are the connectors for the powerline communication bus.
PCB on the back of the UTILITY
display:
Utility display dimensions
Key:
A- Touch-screen
B- USB port housing
C- Holes for wall mounting
D- Knockout for electrical cable