1
2
.
.
1
1
1
Note: The operating mode is specified and saved during the teaching process. A
change of the operating mode (e.g. from sensor control to time control) is only possible
by a new teaching process after a reset.
1
Note: In order to change the operating mode of an outlet or to add a sensor, the teaching
process must be restarted.
A reset must be performed for this purpose. The setting process is restarted, beginning with
sensor 1:
Remove the batteries from both sensors and the control unit.
Reinsert the battery in the control unit. As soon as the symbols appear on the display,
press the OK button until the time on the display is flashing.
Reset the time and start the teaching process of sensor 1, then of sensor
2.
* depending on model
Preparation / teaching sensor
Remove the sensor cap of the sensor.
Connect the battery with the battery clip. The con-
3
nected battery is reinserted in the casing with the
.
battery clip going in first.
Close the sensor by means of the sensor cap.
Note: The battery is not included in the scope of deliv-
ery.
As soon as the contact of the radio signal is estab-
lished, the symbol for the radio signal appears per-
manently. It is now guided through the setup se-
quence (preset value for moisture, times, etc.).
Sensor 1 was detected successfully.
*
*
*
2
2
2
Prepare / teaching sensor 2*
*
2
The setting process of sensor 2 starts automatical-
ly after the watering setting of water outlet 1. If the
water outlet 1 remains inactive, teaching of the wa-
ter outlet 2 must be enabled by pressing the OK
button. The seconds countdown starts for water
outlet 2. Teaching of sensor 2 is equivalent to sen-
sor 1.
EN
– 5