Step 1 Find Suitable Location For Water Heater Installation
Consider the following points:
i.
For weight distribution in caravans, the Water Heater must be positioned as close to the axle as possible.
The installer must avoid locating the Water Heater at the very rear and the very front of the vehicle.
ii.
The Water Heater must be located between chassis members to protect it from the curb. The chosen
location must ensure that the Water Heater is protected by chassis members which must be at least
180mm deep.
iii.
Any surfaces in contact with the Water Heater must be rated to at least 70 degrees C.
iv.
The location must allow access for servicing the Water Heater. Allow at least 200mm of space in front of the
water water. This will allow a service engineer to remove the front cover.
v.
The flue terminal must be located at the side of the caravan. Acceptable flue lengths are 0.75 metres, 1.25
metres and 2 metres. The flue is supplied in 2.0m, 1.25m and 0.75m lengths. A flue maybe shortened to a
minimum length of 0.75m, but must not be cut any shorter than this. Flues must not be lengthened.
vi.
The flue terminal must be positioned at the side of the vehicle, that an awning will never be fitted to.
vii.
Only the Whale flue terminal (supplied with the Water Heater) is permitted to be used in conjunction with this
Water Heater. This flue must not be positioned within 500mm of a refuelling point or fuel tank breather outlet
or any ventilator from the fuel system(s). The flue terminal must not be fitted within 300mm of a ventilator for
the living space or an opening part of a window.
viii.
The flue terminal must only be positioned vertically below an opening part of a window, if the appliance is
fitted with an automatic shut-off device to prevent operation when the window is open. The flue terminal
must be a minimum of 300mm below the window.
ix.
If supplied with a reset button, the user must be able to access it to clear lockouts.
Step 2 Cut Out Hole for Underfloor Water Heater
The cut out in the floor and hole positions are shown in Fig. 9.
A cut out template is available on request by contacting Webasto.
9mm Bolt Holes
9mm Bolt Holes
INSTALLATION INSTRUCTIONS - UNDERFLOOR MODELS
Whale Part Numbers: WW0821U (Suffix: B or R or C)
Fuel refuelling
/ breather vent
Min 500mm
Fig. 8 Installation Locating Diagram - Underfloor Installation
9mm Bolt Holes
Fig. 9 Cut Out Hole In Floor - Underfloor Installation