ELECTRICAL CONNECTIONS

Electrical Rating

This heater is designed to operate at 120 or 240 VAC. It is not recommended to be connected to OR operate on a 208 VAC.
• The MiniMax NT heater is prewired for 240-volt AC connection using the "RED" connector and the "BEIGE" common connector;
see
Figure 16
below. For 120-volt AC supply, remove the "BEIGE" common connector and plug it into the "BLUE" common
connector.
• When connecting the power supply to the "Line Terminal Block" inside the junction box, follow the polarity as shown below.
Connecting to 120 VAC, make sure that you connect the wire to the terminal (L), the neutral wire is connected to the neutral
terminal (N) and the ground is connected to the ground terminal (GND); see below,
• If any of the original wiring supplied with this heater must be replaced, installer must supply (No. 18 AWG, 600V, 105° C.
U.L. approved AWM low energy stranded) copper wire or it's equivalent. Thermal fuse wiring must be replaced with 18 AWG,
600V, 150° C. temp. rating.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas and Propane Installation Codes. If an external electrical
source is utilized, the heater, when installed, must be electrically grounded and bonded in accordance with local
codes or, in the absence of local codes, in the USA, with the National Electrical Code, ANSI/NFPA 7; in Canada, with
Canadian Electric Code, CSA C22.1.
Always use crimp type connectors when connecting two wires.
Figure 16.
Rev. E 4-15-05
60 Hz
120 / 240 Volts AC, single phase
TRANSFORMER
CONNECTOR
BEIGE
COMMON CONNECTOR
RED
240V CONNECTOR
LINE TERMINAL BLOCK
GREEN WIRE
INTERNAL
WHITE WIRE
FACTORY WIRES
BLACK WIRE
CAUTION
NOTE
CAUTION
BLUE
120V CONNECTOR
TERMINAL BLOCK
120 / 240 VOLT SINGLE
PHASE "See Below"
GROUND
CONNECTION
NEUTRAL / WHITE 120 VAC
LINE #1 FOR 240 VAC
N
HOT / BLACK 120 VAC
LINE #2 FOR 240 VAC
L
Figure
17.
FOR AC INPUT
You need to open the right
door then remove the
control panel cover for
servicing the Line Terminal
Block as shown in Figures
16 & 17, (see item 40 in the
exploded view on
Figure 17.
19
page
33).
P/N 472235