GB
Once the preceding points have been observed, it only means that the state of the stove
has been veri ed. It is necessary to thoroughly clean the smoke discharge tube or ue
and check the condition of the basket. If necessary, order a new one from our Authorized
Assistance Centre. If necessary, lubricate the hinges of the door and the handle. Also
check the ceramic bre cord near the glass, on the internal wall of the door; if it is worn
or too dry, order a new one from the Authorized Assistance Centre.
7.0
Annual maintenance performed by qualified
personnel
The following operations are to be programmed annually and are necessary to insure
that the product remains ef cient and guarantee safe operation.
• Careful cleaning of the combustion chamber;
• Cleaning and inspection of the smoke clearing ducts;
• Checking the seal of the gaskets;
• Cleaning the mechanisms and moving parts (motors and fans);
• Checking the electrical parts and the electronic components.
7.1 Operations to perform every season before the rst lighting
• A general cleaning inside and outside;
• A careful cleaning of the exchange tubes;
• A careful cleaning and disincrustation of the crucible and the relative cavity;
• Clean the motors, checking the play and fastenings of the mechanisms;
• Clean the smoke channel (substitute the tube gaskets) and smoke extractor fan ca-
vity;
• Clean silicone tube connected to the pressure switch;
• Clean, inspect and disincrust the lighting resistor cavity, replacing it if necessary;
• Clean/check the synoptic panel;
• Visually inspect the electrical cables, the connections and the electrical power cable;
• Clean the pellet container and verify the play with the screw feeder gear motor;
• Replace the door seals;
• Functional assessment, loading the screw feeder, lighting, 10 minutes of operation
and shut down.
184
123
Model:
MIA 2 - 7.5
Heating input (min-max):
Nominal heat output:
Reduced heat output:
CO emissions at 13% O2 (nominal heat):
CO emissions at 13% O2 (reduced heat):
Ef ciency at nominal heat output:
Ef ciency at reduced heat output:
Flue gas temperature at nominal heat output:
Flue gas temperature at reduced heat output:
Draught (min-max):
Voltage:
Frequency:
Electrical comsumption (ignition):
Electrical comsumption (working):
Weight (with door):
Exhaust gas flow (at rated power)
Exhaust gas flow (reduced power)
The indicative heatable surface is 229 m
WARNING!
In case of re inside the chimney,
immediately contact the re ghters.
521
16
3,38 kW -7,29 kW
6,66 kW
3,11 kW
0,016 %
0,032 %
91,26%
91,86%
142,5 °C
87,2 °C
10-12 Pa
230 V
50 Hz
280 W
100 W
73
kg
5,0 g/s
4,0 g/s
3
455
MIA 2 - 7.5