4.2 How to set current hour - MN02
• Press key 1 and then key 3 repeatedly until the code MN02 appears on the display.
• Press keys 1 and 2 to select the minutes. Hold the buttons to scroll faster.
4.3 How to set the current minutes - MN03
• Premere il tasto 1 e poi ripetutamente il tasto 3 no a far apparire MN03 sul display.
• Premere i tasti 1 e 2 per selezionare i minuti. Tenere premuto i pulsanti per scorrere
più velocemente.
CHRONOTHERMOSTAT –MN05 - MN06 - MN07 - MN08 - MN09 - MN10
The chronothermostat FUNCTION enables to programming automatic starts and stops
of the stove.
4.4 How to programm
Referring to the program 1
• Press key 1 and repeatedly key 3 until the code MN05 appears.
• Press the keys 1 and 2 to vary in steps of 10 minutes the time of automatic turn on.
Press and hold the buttons to scroll faster.
• Press key 1 and repeatedly key 3 until the code MN06 appears.
• Press the keys 1 and 2 to vary in steps of 10 minutes the time of automatic turn off.
Press and hold the buttons to scroll faster.
• Press key 1 and repeatedly key 3 until the code MN07 appears.
• To enable the function TIMER1 set MN07 "ON" by pressing key 2 the Timer LED and
this will light.
• To disable the function TIMER1 set MN07 "OFF" by pressing the key 2 the LED Timer,
in case the Timer 2 is not enabled, it will turn off.
Same procedure with the program 2, but You'll only use the codes MN08 - MN09 -
MN10.

5.0 Alarm codes

BLAC OUT
: In the event of an even very short lack of current, the stove switches off.
As soon as the power supply is back, the stove will start a cooling cycle and the display
will show the words "BLAC OUT". After completing the cooling cycle, the stove will start
up again.
SERV
: The signal "SERV" on the display means that the stove has reached 900 hours
working. Please contact an authorised technical service to arrange a supplementary
maintenance.
ALAR/FAN/ACC
: This alarm occurs when the time foreseen for a light up (around
15 minutes) passes and the smokes temperature is still too low. This can occur also
when there is not enough pellets ow to light up the unit. Press the key On/Off on the
control board to reset the alarm. Wait until the cooling phase is completed, clean the
brazier and start up with a new switching on.
ALAR/NO/FIRE
: This alarm occurs in the event the stove switches off during its
working phase (for example if there is no pellets left in the pellets tank). You will read
the words "ALAR/NO/FIRE" on the display. Press the key On/Off on the control board to
reset the alarm. Wait until the cooling phase is completed, clean the brazier and start
up with a new switching on.
ALAR/FAN/FAIL
: This alarm occurs in the event the smokes ejector is broken
or the pcb cannot detect the speed of the smokes exhaust fan. In this case press the
key On/Off to reset the alarm and contact the technical assistance.
ALAR/SOND/FUMI
: This alarm occurs in the event the sensor for smokes tem-
perature is broken or not connected. You will read the words ALAR SOND FUMI on the
display. In this case press the key On/Off to reset the alarm and contact the technical
assistance.
ALAR/DEP/SIC/FAIL
: This alarm is signalised by the Led ALC blinking on the
control board. It indicates two different possibilities: an obstruction in the ue or a pos-
sible overheating of the stove. In both cases the motor reducer to load the endless screw
stops working and the stove switches off. Press the key On/Off to reset the alarm. Check
the possible activation of the manual reset thermostat on the back of the stove (4). Un-
screw the safety cap and press the key.
Day
In the event you have the same problem more than once, please contact the technical
Monday
assistance.
Tuesday
Wednesday
Thursday
ALAR/HOT FUMI
Friday
the SHUTDOWN procedure. The display will show "ALAR / HOT /FUMI". The alarm is still
Saturday
on the display until the user doesn't reset the allarm press the key 3 ( on/off ) for 2 se-
Sunday
conds.

6.0 Cleaning and maintenance

Before effecting any maintenance operation or cleaning on the stove, take the following
precautions:
• Be sure that all parts of the stove are cold.
• Be sure that the ashes are completely cold.
• Be sure that the general switch is in the "OFF" position.
• Be sure that the plug is pulled out of the socket to avoid accidental contact.
• Once the maintenance phase is completed check that everything is in order as per
before the intervention (the brazier is placed correctly).
6.1 Cleaning of the combustion chamber (once a month)
When the stove is off and cold:
- Open the stove front door, remove the grate, the ashes-pan and the bottom of the
combustion chamber (Pic. 1-2)
- Extraction of the re protection: push the re protection upward to remove it from the
slot (Pic. 3). Unscrew and remove the upper bulkhead (Pic. 4-5).
- Unscrew and remove the central bulkhead of the combustion chamber (Pic. 6-7).
- Now using a brush and a vacuum cleaner, clean top and bottom of the combustion
chamber by removing all ash which has built up inside the combustion chamber (Pic.
8-9).
- Reassemble everything in reverse order.
14
: If the Smoke temperature goes over 280°C then: the PCB begin
reset button
thermostat
Follow carefully the following cleaning instructions. Failure to follow
these instructions could create problems with the operation of the
stove.
Pict. 1
Pict. 2
Pict. 4
Pict. 5
Pict. 3
Pict. 6