Specifications
1-1 General Specifications
Jaw opening: 0.5" (12.7mm) Accepts up to 1/0 copper
cable.
LCD display digits: 6000 digit large scale LCD readout.
Measuring rate: 5 times / sec.
Overrange display: "OL" is displayed for "Ω" function,
shows the real value for "A" and "V" function.
Automatic power off time: Approximately 30 minutes
after power on.
Low battery indicator:
battery when the indicator
Power requirement: 9V battery
Battery type and life: ALKALINE PP3, 9V 250 hours
1-2 Environmental Conditions
Indoor Use.
Calibration: One year calibration cycle.
Operating temperature: 0°C ~ 30°C ( < 80% RH)
30°C ~ 40°C ( < 75% RH)
40°C ~ 50°C ( < 45%RH)
Storage temperature: -20 to +60°C, 0 to 80% RH
(batteries not fitted)
Operating altitude: 2000m (6562 ft)
Overvoltage category:
IEC 61010-1 CAT IV 600V
CAT III 1000V
IEC 61010-1 CAT IV 600V
CAT IV equipment of OVERVOLTAGE CATEGORY IV is for use at
the origin of the installations. Note examples include electricity
meters and primary over-current protection equipment.
Conductor Size: 27mm diameter
Pollution degree: 2
EMC: EN 61326-1
Shock vibration: Sinusoidal vibration per MIL-T-
28800E (5 ~ 55 Hz, 3g maximum)
Drop Protection: 4 foot drop to hardwood on concrete floor
1 - 3 Electrical Specifications
Accuracy is ± (% reading + number of digits) at 23°C ± 5°C
< 80%RH.
Temperature coefficient:
0.2 x (Specified accuracy) / °C, < 18°C, > 28°C.
Voltage
Function
Range
V~
1.3 ~ 750.0V
1.8V ~ 1000V
V
-0.6V ~ -1000V
Overload protection: 1000 VDC / 750 VAC
Max Operation time: DT=30s for ≥ 30V
Input impedance: ≥ 4K for input voltage up to 30V.
Impedance increases with input voltage to approximately
200KΩ at 600V.
is displayed. Replace the
appears in the display.
Accuracy
±(1.5%+3dgt)
50Hz ~ 500Hz
±(1% + 2 dgt)
±(1% + 4 dgt)
7
Resistance & Continuity
Function
Range
0.0Ω~99.9Ω
)
)
Ω
)
)
100Ω~2000Ω
*Temperature coefficient multiplies by 1.5 when operating
temperature is 40°C ~ 50°C.
Overload protection: 1000 VDC / 750 VAC
Max. open circuit voltage: 1.5V
Continuity check: Internal beeper activates if the resistance
of the circuit under test is less than 25Ω. It will then turn off
if the resistance is increased beyond 400Ω.
AC Current
Function
Range
A~
0.6A ~ 200.0A
Overload protection: 400A ±(1.8% +6 dgt) for < 50A.
Max. open circuit voltage: 1.5V
Continuity check: Internal beeper activates if the resistance
of the circuit under test is less than 25Ω. It will then turn off
if the resistance is increased beyond 400Ω.
Warranty Statement
This tester is warranted to the original purchaser against
defects in material and workmanship for two years from
the date of purchase. During this warranty period, IDEAL
INDUSTRIES, INC. will, at its option, replace or repair the
defective unit, subject to verification of the defect or
malfunction.
This warranty does not cover fuses, batteries or damage
from abuse, neglect, accident, unauthorized repair, alteration,
or unreasonable use of the instrument.
Any implied warranties arising out of the sale of an IDEAL
product, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are
limited to the above. The manufacturer shall not be liable
for loss of use of the instrument or other incidental or
consequential damages, expenses, or economic loss, or for
any claim or claims for such damage, expenses or economic
loss.
State laws vary, so the above limitations or exclusions may
not apply to you. This warranty gives you specific legal
rights, and you may also have other rights which vary from
state to state.
Accuracy
±(2% +1Ω)
±(2% +2 dgt)*
Accuracy
±(1.8% +3 dgt)*
50Hz ~ 60Hz