AMR PULSE W-Mbus- Mode d'emploi / User guide version V1.1
Serial number
A-Field
Device version
Device type
Code de trame
CI-Field
Short header
DATA-Field
Check Encryption
Historic type
Primary VIF
Secondary VIF
Value type
Sample rate
Historic number
Time Tag
Partial frame
DATA Field
Nb of value type data
Historic value
Historic value
RSSI
Signal reception level
5. Document history
User guide version
V1.1
V1.0
Function code 0x02
Access num-
ber
Status
Signature
Contents
English version
Document created
1
0x14040019
Read
9000414 (note: <
2
<
>, designates meter no. 2)
0x03
Product version
0x07
Idem product type data frame
0xAD
History frame
0xB5
Incremented on each new frame = historic number
0x00
Product status
0x00
No encryption
0x00
0x2F2F
always 0x2F2F (for encryption verification)
0x01
Type historique 24h (0x02: 7 jours, 0x03: 31 jours,
0x04: 1 an, 0x05: 3 ans)
0x13
Information concerning history data units: 1dm3, ie. 1
litre
0x00
Not used
0x02
Data 8 bits unsigned
0x080700
Sampling of history data: read 000708 (Hex) -> 1800
sec
0xB5
history number incremented on each new frame
0x000015
Period between the last data saved and the history is
sent = 21 s
0x00
Number of frames to come
0x02
Number of value type function data
0x36
36 in hexadecimal = 54 dm3, ie 54 litres
0x30
30 in hexadecimal = 48dm3, ie 48 litres
BF
RSSI of the frame received: RSSI value = -125 + (x
* 0.5), ie in this example BF = 191, RSSI = -125 +
(191*0.5) = -29.5dBm
1
> designates meter no. 1,
Page
43