  • FRANÇAIS, page 32
The temperature of
the water is too warm
Water
constantly
present on bottom of
container
The lighting doesn't
work
The hood is blocked
or difficult to move
(in
models
with
opening hood)
The water loading
does not work
dA alarm displayed
EA alarm displayed
ATTENTION:
In order to work the bathtub correcly it must be filled up of water until exceeding the level
sensor
The heating circuit cuts out
There is too much water in the
tray
The thermoregulator is not set to
the correct position
The drain system is full
The water drain is blocked
The machine is not plugged into
the current socket
The
power
supply
damaged or interrupted
The main bipolar switch is off
The machine main switch is off
There is a current interruption on
the control panel
The lighting switch is off
The lighting are broken or there's
been a power failure
The
superstructure
system is damaged
The steel cords supporting the
upper part are damaged
Solenoid valve is broken or
missing water.
Missing water inside the tray
Incorrect parameters
CT68900002 Rev.0 09-13
Check the condition of the heaters and/or
thermal cut-out switches. If necessary, contact
the manufacturer or your local dealer and have
them replaced with identical products
Check the water level in the tray and bring it to
the level shown in chapter 13
Adjust the thermoregulator
Drain the water by pulling the plug located to
the left of the control panel (front view) or by
turning the drain tap
Check that there are no impurities in the
container drain hole
Plug the machine in correctly
cable
is
Check the condition of the cable. If necessary
contact a qualified technician to replace it with
another one of the same type
Turn the mains bipolar switch on.
Turn the machine main switch on.
Check the condition of the control panel. If
necessary contact a qualified technician to
restore the current
Turn on the lighting switch
Check the condition of the lighting. If
necessary, contact a qualified technician to
replace it with identical lighting
supporting
Check the condition of the system. If necessary
contact the manufacturer or authorised dealer
for replacement
Check the condition and smooth running of the
cords. If necessary, contact the manufacturer or
authorised dealer for replacement
Check the state of solenoid valve. Check water
pressure feed.
Load water inside the tray.
Reset the thermoregulator.
Contact technical assistance.