Télécharger Imprimer la page

Stid Architect Blue Serie Notice D'installation page 2

Publicité

Les langues disponibles

Les langues disponibles

ARCS Blue
Upgradable readers
Installation instructions
ARCS-
X: A: Standard
X/BT1
B: Keypad
C: Touch screen
ARCS-XC/BT1
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN 62368-1) for the
main supply.
Main power supply:
Range: +7 Vdc to +28 Vdc
Max. consumption at 12 Vdc:
ARCS-A/BT1: 150 mA
ARCS-F/BT1: 370 mA
ARCS-K/BT2: 250 mA
Communication:
RS485 (L+ & L-) / TTL (Wiegand / Clock and Data)
Connection:
Removable connectors 1x10 pins and 1x2 pins, thread 0.19685 inch OR cable.
Protection:
IP65, excluding connectors
ASSR-1218-003E: 60 V output withstand voltage / 0.2A current rating / low on-resistance 1 Ω typical for AC/DC
Static relay:
Screw terminal output:
Cable output (cable supplied): TRANXALARM - 14x0.22mm2 - lg 3,05m.
The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (R3x & S3x) or controlled by the remote system with a 0 Vdc
respectively on the "Led 1", "Led 2" and "Buzzer" inputs of the reader's connector or controlled by the communication protocol of the reader (W3x).
Tearing is detected by an accelerometer. When the reader is wrenched, the switch output (connector J2) provides an O/C contact to indicate the tearing of
reader.
for R/S 31/x1: the wrenching signal will be emitted on the "Data/Data1" line. This function is configurable via a configuration card.
for R/S 33/x3 and OSDP
for W33/x3: the reader will perform the operations configured with the SSCP protocol.
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
STid reserves the right to make change without notice, for the purpose of product improvement.
Screw terminal output product references
D: Standard + Biometrics
E: Keypad + Biometrics
F: Touch screen + Biometrics
J6: Antenna connector
J7: Keypad connector
J9: Biometric connector
J14: Display connector
J2: O/C contact
Cable output product references
X:
A: Standard
B: Keypad
C: Touch screen
J6: Antenna connector
J7: Keypad connector
J9: Biometric connector
J14: Display connector
J15: Output cable
ARCS-B/BT1: 180 mA
ARCS-I/BT2: 180 mA
ARCS-KM/BT2: 260 mA
RS485:
Use a multi-conductor shielded twisted pair cable. Max. length: 3281 ft at 9600 baud
Wiegand / Clock & Data:
Use an untwisted shielded multi-conductor. For data:
2 wires AWG24 – 98 ft max / 4 wires AWG24 – 197 ft max / 6 wires AWG24 – 328 ft max
2 wires AWG20 – 164 ft max / 4 wires AWG20 – 328 ft max
TM
: the reader will perform the operations configured with the configuration card.
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1114C08- Page 1 sur 18 - Ed. 08/12/2020
ARCS Blue
Lecteurs évolutifs
Notice d'installation
AQ: Standard + QR Code
BQ: Keypad + QR Code
CQ: Touch Screen + QR Code
Connector
J4
1
2
3
4
5
6
7
8
9
10
D: Standard + Biometrics
E: Keypad + Biometrics
F: Touch screen + Biometrics
1
Dark blue
2
Pink
3
Orange
4
White
5
Yellow
6
Red
7
Blue
8
Grey
9
Green
10
White Brown
11
White purple
12
Brown
Power supply characteristics
Typical: 12 Vdc
ARCS-C/BT1: 220 mA
ARCS-D/BT1: 300 mA
ARCS-IM/BT2: 190 mA
ARCS-J/BT2: 210 mA
ARCS-AQ/BT1: 260 mA
ARCS-BQ/BT1: 300 mA
Characteristics
Recommended cables
Buzzer / LED
Anti-tearing
ARCS Blue
Lectores escalables
Procedimiento de instalación
conforme con NOM-024 -SCFI-2013
ARCS-
X: I / IM: Standard + 125 kHz module
X/BT2
J / JM: Keypad + 125 kHz module
K/ KM: Touch screen + 125 kHz module
Type
Wiegand
Clock & Data
RS485
0 Vdc
+Vcc (+7 Vdc to +28 Vdc)
D0
Code
NC
D1
Data
NC
Clock
Clock
NC
L+
NC
NC
NC
NC
Led 1
Led 2
Buzzer
Type
Wiegand
Clock & Data
J15
SW2
SW1
Led 2
Buzzer
Clock
Clock
+Vcc (+7 Vdc to +28 Vdc)
D1
Data
D0
Code
Led 1
NC
NC
NC
NC
0 Vdc
ARCS-E/BT1: 330 mA
ARCS-JM/BT2: 220 mA
ARCS-CQ/BT1: 340 mA
US
FR
ES
L-
RS485
NC
NC
NC
L+
L-

Publicité

loading