INSTALLATION
Installing/Replacing the lamp
For the installation, you need one MSD/HSD 200 GY-9.5, MSD/HSD 250 GY-9.5 or MSD 250/2 GY-9.5
lamp.
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp or check the operating hour meter regularly and replace the lamp in time.
Keep exchanged lamp in a protective container and remove accordingly.
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
Procedure:
Step 1: Unscrew the lens screws.
Step 2: Remove the transport safeties (foam rubbers) between the color filters and the lens completely.
(Only necessary at intitial start-up!)
Step 3: Remove the lens.
Step 4: Unscrew the reflector screws and remove the reflector.
Step 5: If replacing the lamp, remove the old lamp from the lamp holder.
Step 6: Insert the lamp into the lamp holder.
Step 7: Replace the reflector.
Step 8: Replace the lens.
Step 9: Tighten the lens screws.
Installation
This device is constructed for a standing installation only.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened cover!
Permanent installation is recommended!
18/43
00026452.DOC, Version 1.1