4. Configuration
CF08 - Opening detection function
0
1
If a door/window magnetic contact (e.g. window) is associated with
the receiver, the heating will switch to Frost protection when the
window is opened.
CF09 - Presence detection function
0
1
If a motion detector is associated with the receiver, the
temperature will be lowered automatically in the event of an
extended absence:
• 1.5 h -> Active setting -1.5°C
• 3.5 h -> Active setting -3.5°C
• 48 h -> Frost protection setting
CF10 - Value of the max. comfort setting
Can be set from 22°C to 30°C.
Default value: 28°C
CF11 - Programming format
0
1
Disabled
Enabled
Disabled
Enabled
Programming in 1 h steps
Programming in 1/2 h steps