Victron energy CAN-bus Manuel page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Connection
CAN Bus connector for
setting the temperature
threshold using TSConfig
software
Pin 1
Connections on 5-pin connector
Pin
1 + 12/24V feed (Note: do not use pin 1 at the same time as the CAN-bus cable!!!)
Pin 2
GND/Min/Earth
Pin 3
+ input (no function)
Pin 4
(no function)
Pin 5
- switched output to earth/GND, active in the event of a temperature alarm
LED indicators
LED colour
LED indication
Green
Green 1 sec, thereafter red
Green LED flashes 1x every 4 seconds
Green LED flashes 3x
Red / Green
A short red flash, followed by 3x green
A long red flash (1 second)
Red
Red LED flashes 3x every 4 seconds
Red LED lights up for 1 second
Red LED flashes 1x every 4 seconds
Technical specification
Dimensions
Weight
Supply voltage
Electricity consumption
Alarm output (pin 5)
6
LED red/green
5-pin connector
Status indication
Starting up
The temperature is above the threshold value set
The CAN-bus temp sensor has received a new threshold value
from the 800/1600
CAN bus connection
Stand-alone Mode, no CAN Bus connection
The CAN-bus temp sensor (still) does not have a valid threshold
value
The temperature has reached the set threshold value (alarm
status active)
The temperature has reached the set threshold value
57.6 x 40 x 15.8 mm (LxWxH) (incl. connectors)
12 grams
4..36VDC
60 mA (@13.6V)
350 mA Open connector (switches to GND/Earth)

Publicité

Table des Matières
loading

Table des Matières