3. CLEANING OF THE FILTER
u
inlet connector
water supply
pipe
water
supply switch
1. Close the water supply valve then remove the water supply line from the inlet adapter.
2. Unscrew the bracket bolt and remove the filling valve.
3. Unscrew the filling valve nut, remove the inlet connector, the filling valve and filter.
4. Clean the filter screen with water.
5. Place the cleaned filter in the filling valve and close the filling valve nut.
(Note: the filter is located in the opening of the filling valve).
6. Now continue as described in the section 2.2 - Filling valve installation and water level adjustment.
y
filter
inlet connector
nut
4. TROUBLESHOOTING
Issue - Cause - Resolution
Water line is too high or too low.
Inlet valve is not set correctly. Adjust the water level to the appropriate water level.
Inlet valve does not close properly.
The cistern/tank is clogged or calcified. Adjust the flushing valve again and make sure that the float can move freely.
The refill tube wasn't installed properly. See figure attached 3.7 to re-install refill tube correctly.
Leakage of flush valve. Check the flush valve for damage.
The water level is above overflow pipe of flush valve. Re-adjust water level to appropriate.
Inlet valve does not open correctly.
Shut-off valve is closed. Turn on the water supply valve.
The float on the inlet valve hangs. Adjust the flushing valve again making sure that the float can move freely.
The filter is clogged. Clean the filter´s sieve.
CT1099
(Filter which is located inside the inlet valve shank should be periodically cleaned).
v
bracket
bolt
overflow
tank
pipe
z
water supply
pipe
tank
water
supply switch
w
filter
inlet connector
nut
{
Wrongly placed refill tube
water level
x
filter
Correctly adjusted refilling tube,
make sure tube is above the water line
5