LaserLiner LiveCheck Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
The socket outlet with earthing contact CEE 7/4 Type F is not
!
protected against polarity reversal. The warning „L/N Reverse"
should therefore also be considered as correct. It is recommended
to use uniform socket wiring throughout the building installation.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning
agents, scouring agents and solvents. Store the device in a clean
and dry place.
Technical data
Voltage range
Frequency range
Indicator
Overvoltage category
Humidity
Degree of protection
Storage temperature
Operating temperature 0°C ... 40°C
Dimensions
Weight
Subject to technical alterations. 01.16
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info
230 V ± 10%
50 Hz
Error mode with 3 indicator lamps
CAT II – 300 V
Pollution degree 2
Max. 80% relative air humidity
(no condensation)
IP20
-10°C ... 70°C
62 x 62 x 66 mm (W x H x D)
57 g
LiveCheck
GB
07

Publicité

Table des Matières
loading

Table des Matières