GB
temperatures, altitude and humidity, compared with
that stated in the operating conditions.
The generator is driven by a combustion engine,
•
which produces heat in the range of the exhaust
(on the opposite side of the socket) and exhaust
outlet. You should therefore avoid coming near
these surfaces because of risk of skin burns.
The values quoted in the technical data under
•
sound power level (LWA) and sound pressure lev-
el (LpA) are emission values and not necessarily
reliable workplace values. As there is a correla-
tion between emission and immission levels, the
values cannot be taken to reliably determine the
possible need for additional precautions. Factors
influencing the current immission level of the user
/ operator include the properties of the work area,
other sound sources etc., e.g. the number of ma-
chines and other neighboring processes, and the
time span over which the user / operator is subject-
ed to the noise. Also, the permitted immission level
can vary from country to country. Nevertheless, this
information makes it possible for the user to be able
to make a better assessment of the dangers and
risks involved.
Important: Use only normal, unleaded petrol as
fuel.
m WARNING
Read all the safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions
in a safe place for future use.
6. Technical data
Generator
Protection type
Continuous rated power P
(S1)
Maximum power P
(S2 2 min)
max
Rated voltage U
nenn
Rated current I
nenn
Frequency
Drive engine design
Displacement
Fuel
Tank capacity
Engine oil
Consumption at 3/4 load
Weight
Sound pressure level L
pA
20 І 104
Synchronous
IP23M
2600 W
nenn
2800 W
2 x 230 V~
11,3 A
50 Hz
4-stroke
208 cm³
unleaded Petrol
This device may
not be operated
with E10 petrol
13 l
approx. 0.6 l
(10W30)
approx. 1.18 l / h
37 kg
74 dB (A)
Sound power level L
WA
Uncertainty K
Power factor cos φ
Power class
Max. temperature
Max. altitude (above mean sea
level)
Spark plug
Operating mode S1 (continuous operation)
The equipment can be continuously operated with the
quoted power output.
Operating mode S2 (temporary operation)
The equipment may be temporarily operated with the
quoted power output 2 min.
The stipulated values are emission values and so do
not necessarily represent safe working values.
Although there is a correlation between emission lev-
els and exposure levels, it is not possible to reliably
determine whether additional protective measures
will be required or not based on this. Factors that
could influence the exposure level present at any
given time in the work area include the duration of ex-
posure, the nature of the working area, other noise
sources etc. e.g. the number of machines and neigh-
bouring processes. The permitted workstation values
can also vary from country to country. However, this
information should enable the operator to better eval-
uate the hazards and risks.
7. Before starting the equipment
Assembly
The installation of the equipment requires two
open-ended wrenches (size 12).
•
Assemble all parts before filling in fuel and oil in
order to prevent the fluids from leaking out.
Assemble the foot (16) , wheels (14) and push bar
•
(18) as shown in Figures E - H.
To mount the wheels, first slide the axle (15)
•
through the mountings on the bottom of the gen-
erator and fit the wheels (14) as shown on Figure F.
Electrical safety
Electric supply cables and connected equipment
•
must be in perfect condition.
The generator is to be operated only with equip-
•
ment whose voltage specifications conform to the
generator's output voltage.
Never connect the generator to the power supply
•
(socket-outlet).
Keep the cable length to the consumer as short
•
as possible.
Environmental protection
Dispose of soiled maintenance material and oper-
•
ating materials at the appropriate collection point.
96 dB (A)
2.3 dB (A)
1
G1
40 °C
1,000 m
F7RTC