Commissioning (incl. pairing)
¾ Activate the pairing function at the base station for the de-
sired heating zone (see base station manual BSB x0xx2-xx).
¾ Press the rotary control >1 s. in order to activate pairing func-
tion.
9 The base station and the room control unit are connected to
each other.
9 If the base station has been programmed before, the date
and time of the room control unit are set automatically.
For first commissioning of the base station:
¾ Set year, date and time by rotating, confirm entries by press-
ing.
Comfort programs - Smart Start/Stop mode
Comfort programs include pre-defined heating times to be used
for working days (1-5) or for the weekend (6-7). Outside the heat-
ing times the installation switches to night mode. You can select
the comfort programs in the Parameter menu. The Smart Start/
Stop Mode of the system calculates the required line-up times
in order to provide the desired temperature at the starting and
finishing time of the heating program.
Programm
P0
P1
P2
P3
You can create individual comfort programs with the on-line
software available under www.ezr-home.de and transfer these
to the basis station with a MicroSD card.
Comfort time 1
05:30 – 21:00
04:30 – 08:30
06:30 – 10:00
07:30 – 17:30
Comfort time 2
–
17:30 – 21:30
18:00 – 22:00
–
DEU
ENG
FRA
NDL
ITA
ESP
27