Furman IT-Reference 20i Guide De L'utilisateur page 10

Conditionneur d'alimentation symétrique discret
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Specifications
AC Current Capacity:
Input - 20 Amp capacity required
Output - 12 - 20 Amp RMS * (maximum, all outlets combined - continuous)
* Due to the Power Factor Technology circuit, available RMS power varies with the reactance of the load (vector). However,
this only affects the circuit breaker for continuous RMS current draw. Since power amplifiers will require high transient current
demands, the IT-Reference 20i will never succumb to current compression. Quite the opposite, in fact, it will buffer the power
amplifier's power supply, while lowering the AC input impedance, allowing power amplifiers to work more efficiently.
Linear Noise Attenuation:
Transverse (Differential) Mode
>20 dB from 1Khz. - 2 kHz.
>40 dB from 2Khz. - 100 kHz.
>80 dB from 100 kHz. – 1GHz.
Linear attenuation curve from 0.05 – 100 ohms line impedance
Common Mode
>95 dB, 10Hz. - 50 kHz.
>40 dB 50kHz. – 1MHz.
Outlets:
8 (symmetrical balanced outlets)
4 (Power Factor Technology outlets • 9 amps RMS reserve • resistive load • over 80 amps pk. charge)
Transient Voltage Surge Suppression:
120VAC Line
Virtually maintenance-free AC surge suppression
Non-sacrificial with zero ground contamination
Telco - Cable / Satellite
Less than .1dB line loss
Dimensions:
5.75" H x 17" W x 15.625" D (standard 3RU without feet)
Weight:
83 lbs.
Power Consumption:
8.5 Watts for display and control circuits independent of actual load.
Safety Agency Listing:
ETL / C-ETL (Pending)
10
IT-R
20
O
'
efeRence
wneR
i
M
s
anual

Publicité

Table des Matières
loading

Table des Matières